beautypg.com

Haltech HT051400 User Manual

Page 9

background image

Status LED Display

The Status Led can display the following information in 3 modes.

1.

Start-up Check

2.

Display Error Codes (if any)

3.

Display Trigger / Home Status when engine is cranking.

Start up Check

To ensure that the Status LED is operating correctly, upon power up of the ECU,
the Status LED will light briefly for approximately 1.2 seconds.

Display Error Codes

Error codes are only displayed if the appropriate diagnostics features are enabled for
each sensor or condition.

Each Code is two digits long

Each digit is displayed as pulses for each digit, with 0.4 seconds between each pulse

After the first digit is displayed / pulsed, there will be a 1.2 second delay to
separate the digits

Consecutive codes are separated by 2 second delay

End of code to start of code display again is separated by 4.5 seconds.

Error Codes

Code

Description

11

Coolant temperature sensor fault

12

Air Temperature sensor fault

13

MAP sensor fault

14

Fuel Pressure sensor fault

15

Fuel Temperature sensor fault

16

Oil Pressure sensor fault

17

Oil Temperature sensor fault

18

Internal Baro sensor fault

19

EGT sensor fault

Display Trigger / Home Status

When the engine is cranking, the LED displays the Trigger / Home status.
The status is displayed as a single, double or triple flash.
Each flash is separated by 0.4 seconds, with a 1.2 second pause between
each status display.

If only Trigger detected, single flash

If only Home detected, double flash

If Trigger and Home detected, then triple flash displayed

The Status light will be disabled when the engine RPM exceeds cranking RPM.

Digital Pulsed Outputs (DPO)

Digital Pulsed outputs are capable of outputting pulsed waveforms with varying duty
and frequency. DPO's can be used to control various devices such as thermo fans,
shift lights, bypass air control valves, boost control solenoids etc.
When a Digital Pulsed output is activated by the ECU the output will switch to ground.
Solenoid valves and shift lights etc can be run directly from the output, however
high current devices such as thermo fans and additional fuel pumps must be activated
through a relay. This way the DPO is only switching a relay and not a high current draw
device.
Digital Pulsed Outputs are limited to 800mA Max current draw.

Digital Pulsed Inputs (DPI)

Digital Pulsed Inputs are capable of accepting pulsed input information such as for a
road speed sensor. These inputs measure the time periods between the pulses and can
process this information to provide quantities such as road speed.

Digital Switched Inputs (DSI)

Digital Switched Inputs are capable of accepting on/off type of input information such as
from a switch. The active state of these inputs is when the input is connected to Ground.
The inactive state is when the input is not connected to Ground. The input active state
can be inverted by selecting an option in the Main Setup Page, so that connecting an
input to Ground results in an inactive state and disconnecting the input results in an
active state.

Analogue Voltage Inputs ( AVI )

Analogue Voltage Inputs accept variable voltage inputs from 0V to 5V. These inputs
can also accept switch inputs that change between two different voltage levels.
The On Voltage and Off Voltage define what the thresholds are between the On and Off
states. The Voltage can be viewed as a channel in the software to determine the
thresholds for a switched input.

High Tension Leads (spark plug leads) / Capacitive Discharge Ignition Units (CDI )

High tension leads and CDI units can cause significant noise or interference on the ECU
wiring.
Keep all ignition wires a minimum of 100mm from any other wires and ECU
components. If ignition wires must be crossed, ensure wires cross ignition leads at right
angles. Keep power and grounding points separate to those used for ECU.

Wire connections

When using crimp connectors ensure that the correct crimping tool is used
Solder all connections where possible.