Guardian Technologies H3000 User Manual
Page 5

E-8
E-9
PROBLEM
SOLUTION
Water vapor & humidity are
not produced.
Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try
again.
Tank Installation: Make sure the water tank is
correctly attached.
Air blows but water vapor is
not produced.
Excessive Water: Remove a certain amount of
water from the tank.
The desired humidity is lower than the current
temperature: Increase the desired humidity.
Detergent residue in the tank: Wash the tank out
and try again.
Humidity level is low.
The surface of the ultrasonic metal circle may be
dirty: Wipe it off with a dry, soft cloth.
The water in the unit is too cold: Replace with cool,
but not cold water.
Damage on the ultrasonic metal circle:
Contact customer service at 1.866.603.5900.
Warm humidity is not produced.
It may take 10-15 minutes before warm
humidity is created. The steam may not feel warm
to the touch.
The humidity has a bad smell.
Poor maintenance or dirty water: Clean the product
thoroughly, and fill it with fresh water.
White dust is forming on nearby
furniture.
Hard water will deposit a certain amount of dust.
Dust in the air settles because of the added
humidity in the room. Use distilled water if this
becomes a nuisance.
My current humidity will not go
below 25%.
The unit will not display a humidity setting below
25%. This means the current humidity in your room
is at or below 25%.
•
Always unplug the unit before servicing it in any way.
•
Be careful when handling the water if warm humidification was selected.
The water temperature of the water remaining in the unit after use may be high.
•
Do not submerse the unit in water, or allow water to enter anywhere on the unit
except the designated water tank.
INSIDE THE BODY OF THE UNIT
Wash out the unit with fresh water, using the cleaning brush and a soft cloth.
Ultrasonic Metal Circle:
Humidity levels become weak when water spots remain on the surface of the
ultrasonic metal circle.
Do not use chemicals or detergents.
OUTER SURFACE OF THE UNIT
Wipe the surface of the unit with a damp cloth if needed. Do not use any type of cleaning
chemical as it may corrode the surface.
WATER TANK
If water spots remain in the water tank, wipe the inside with a soft cloth. Do not use soap or
detergents. Silver Clean particles have been added to the water tank to help fight the growth
of mold, mildew and bacteria.
AIR FILTER
Gently wipe away debris from the filter with a soft cloth.
ULTRASONIC DISK
Remove spray spout (Fig. 1) and use the enclosed cleaning brush to regularly remove build up
and deposits from this area (Fig. 2). White vinegar will help to prevent this build up.
Fig. 1
Fig. 2
•
Fully dry the inside and outside of the unit before storing it.
•
DO NOT leave water in the unit.
•
Store in a cool, dry place.