Guardian Technologies GG1100W & GG1100B User Manual
Pluggable uv-c air sanitizer & deodorizer, Use & care instructions

Germ Guardian
®
Pluggable UV-C Air Sanitizer
& Deodorizer
Model No. GG1100
1-Year Limited Warranty
IMPORTANT SAFETY INSTRUCTIONS: READ AND SAVE
THESE INSTRUCTIONS BEFORE USING THIS PRODUCT
When using this product basic precautions should be followed to reduce
the risk of fire, electric shock and injury.
DANGER: Electrical Shock
•	 Use	this	product	only	as	described	in	this	manual.
•	 Operate	this	product	on	120	V	AC,	60HZ	only.
•	 To	reduce	the	risk	of	fire	or	electric	shock,	do	not	use	this	fan	with	any	
 solid-state speed control device.
•	 Do	not	operate	without	cover	in	place.
•	 Do	not	defeat	the	interlock	switch.
•	 Do	not	operate	with	an	extension	cord.
•	 Do	not	operate	this	product	if	there	is	any	physical	damage	to	the	unit.
•	 This	product	is	for	indoor	use	only.
•	 Do	not	operate	this	product	in	any	area	where	there	is	a	risk	of	the	unit	
	 falling	into	or	being	exposed	to	water.
•	 Opening	windows	or	doors	while	operating	this	device	may	affect	
	 performance.
•	 Always	unplug	the	unit	before	servicing.
•	 Close	supervision	is	necessary	when	operated	near	children	and	pets.
•	 Do	not	handle	the	unit	or	plug	with	wet	hands.
•	 Keep	the	product	away	from	heated	surfaces.
•	 Do	not	put	any	object	into	the	openings	or	block	the	airflow	to	the	unit.
WARNING: Electrical Shock
UNDER NO CIRCUMSTANCES SHOULD YOU CLEAN THE BULB,
BULB HOLDER OR CYLINDER WITH WATER OR WET SOLUTIONS.
THIS COULD CAUSE ELECTRICAL SHOCK.
WARNING: Electrical Shock
ALWAYS UNPLUG THE UNIT FROM ELECTRICAL OUTLET WHEN SERVICING.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE WITH AN
EXTENSION CORD.
It is recommended to run the product continuously. Opening doors and/or
windows in the room may affect the performance of the device.
WHEN TO CHANGE THE BULB
A	replaceable	3.5	watt	UV-C	light	bulb	will	last	over	5000	hours.	Over	time	with	
use	the	UV-C	bulb	will	lose	some	intensity	approximately	15%	at	4000	hours.	
Therefore	it	is	suggested	to	replace	the	UV-C	light	bulb	every	6	months	depending	
on	use.	You	will	know	to	change	the	bulb	when	the	light	flickers	continuously	or	
changes color. 
Call customer service at 866-603-5900 to order.
Replacement Bulb LB1000
TROUBLESHOOTING GUIDE
DIRECTIONS FOR USE
1.	 Plug	the	unit	into	a	120V	AC	electrical	outlet.
2.	 For	best	results	continuous	operation	is	recommended.
3.	 Use	the	charging	port	on	the	side	of	the	unit	to	charge	other		
electronic products containing a USB cable.
USE OF THE PLUGGABLE
When	the	Pluggable	is	turned	on	you	will	see	a	ring	of	blue	light	that	lets	
you know it is working.
NOTE: THE PLUGGABLE UNIT CONTAINS NO SERVICEABLE PARTS 
EXCEPT ITS UV-C BULB. THE BULB MAY BE REMOVED FOR REPLACEMENT.
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site
Cleanup Requirements. In case of breakage, follow
clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup
1-866-284-4010
HOW IT WORKS
Purified air is released
into the room
UV-C light kills or
inactivates airborne
bacteria
Fan draws in air
USB port
Unit doesn’t operate.
Light flickers.
Fan runs but no light.
Check that unit is plugged in.
Call customer service at 1-866-603-5900
Bulb burnt out. See Replacing UV-C Bulb
section	of	manual.
Bulb	burnt	out.	See	Replacing	UV-C	Bulb	
section of manual.
PROBLEM
SOLUTION
USE & CARE INSTRUCTIONS
PRODUCT SPECIFICATIONS
MODEL NUMBER:	GG1100
POWER:	120V	AC	60Hz,	.4	Amp
REPLACEMENT LAMP:	LB1000,	3.5W
DIMENSIONS:	2.65”L	x	3.50”W	x	6.90”H
WEIGHT:	.65	pounds
REV0914