beautypg.com

GME MT406GAUS User Manual

Page 12

background image

PAGE 12

instruction mAnuAl

406G EPirB

if returning your mt406G to your dealer or GmE branch for service or

battery replacement, you should advise the transportation company

prior that the beacon contains lithium batteries .
Do Not send your beacon through the postal system.
Disposal
special precautions must be taken when finally disposing of your

beacon at the end of it’s useful life . legislation may determine the

specific requirements which apply to you . in the first instance contact

your national Authority for advice .
the following information may also be helpful:
• To permanently disable the beacon remove the 4 screws retaining

the cover, open unit, unplug battery lead, then reseal .

• Lithium batteries are generally not considered as hazardous waste

when fully discharged . Qualified personnel may be able to slowly

and safely discharge the cells for you .

Do Not short circuit the cells or battery. Do Not incinerate.

sPEcIfIcatIoNs - mt406G

MoDEs oF opErAtIoN

Activated:

uHF (406) and VHF (homer) complete with high

intensity strobe and audible activation alert .

self test:

comprehensive internal diagnostics with visual

and audible operator feedback . uHF test message

(inverted synchronisation compatible with portable

beacon testers) .

opErAtIoN

Activation:

manually by operator .

Bracket type:

manual release .

Duration:

48 hours minimum .

transmission Delay:

121 .5 and 406 mHz distress signals commence ~

60 seconds after activation .

Warm Up:

none required (due to digital frequency

generation) .

VHF:

121 .5 mHz, 50 mW ±3 dB, swept tone Am .

UHF:

406 .037 mHz, 5 W ± 2 dB, Psk (digital) .

strobe:

20 flashes/minute at greater than 0 .75 cd

effective intensity .

cospAs-sArsAt

certified to c/s t .001 (class 2) requirements .

UHF-protocol/Data:

national location*, radio call sign or mmsi

(all with GPs location) .

repetition period:

50 s mean, digitally generated randomization .

BAttErY

replacement period:

Prior to expiry date marked on case .

replacement Method:

service centre, or factory only (non-user

replaceable) .