ENGLISH
boiler must be brought down to a brewing temperature. 
Otherwise, espresso may taste “burned”. 
To do this: place an empty cup on drip plate. Do not insert
fi lter holder. Put the hot water/brew switches (2) and 
the steam switch (4) to “1”, letting cup fi ll with water. 
Turn brew switch “0”. 
You may now proceed to make espresso.
Keeping it clean:
1 IMPORTANT: the steam nozzle should be cleaned after
each use in order to avoid build up of milk deposits that 
are very diffi cult to clean. Cleaning is made easy as can 
be seen in the DESCRIPTION OF PARTS. The outer 
part of nozzle can be removed by pulling downward. 
The outside of the steam pipe can be cleaned with a damp
cloth.
The steam jet is cleaned by running a shot of steam
through it.
The hole in the steam nozzle must be kept open. A needle
may be used.
Pay attention as the Turbo-
Frother steam nozzle could
be hot!
Air intake to be kept clean and free
from residues.
2 Clean fi lter holder and fi lter in warm water after use.
3 Wipe body of machine with a damp cloth as required.
4 Remove drip tray and plate (5-12) and wash in warm 
soapy water. Do not use abrasive substances.
5 Clean the seal (15) inside of the brewing head (14) and
keep it clean.
6 The shower disc (17) should be unscrewed and cleaned
periodically depending on frequency of use.
7 After long periods of non-use, drain stale water from
machine by turning hot water/coffee switch to “1”. 
However, do this only after you have fi lled tank with fresh 
water. Never operate pump unless there is water in tank.
8 NOTE: It is very normal for an espresso machine to emit
steam and drip occasionally as the water pressure changes 
during use.
Be certain to empty drip tray (12) as required.
Descaling
Limescale normally builds up with the use of the appliance. 
The machine needs descaling every 1-2 months (if used) 
and/or whenever a reduction in water fl ow is noticed. Use 
the GAGGIA descaling product only. 
NOTE: In case of confl ict, priority must be given to what is
indicated in the operation and maintenance manual over 
the instructions provided on separately sold accessories 
and materials.
NOTE: Use the GAGGIA descaling
product only. Its formula has been 
designed to ensure better machine 
performance and operation for its 
whole operating life. If correctly 
used, it also avoids alterations in 
the brewed product. The descaling 
solution is to be disposed of 
according to the manufacturer’s 
instructions and/or regulations in 
force in the country of use.
NOTE: Never drink the descaling solution or any products
dispensed until the cycle has fi nished. Never use vinegar 
as a descaling solution.
1 Insert the fi lter holder into the brew unit from the bottom
(14) and turn it from left to right until it locks into place.
2 Remove and empty the water tank.
3 (Fig.02) - Pour HALF the content of the GAGGIA 
concentrated descaling solution into the water tank, and 
then fi ll the tank with fresh drinking water up to the MAX 
level.