Backsplash - vertical installation – FloAire Backsplash User Manual
Page 2

# OF DIVIDER BARS = TOTAL DIVIDER BAR LENGTH / 84 + 1 (round up).
Backsplash - Vertical Installation
•
Example (above): Total required divider bar length = (6-1) x 80 = 400. #of Divider Bars = 400/84 + 1= 5.761 = 6 pc.
•
Calculating # Of End Caps - Part # J63-1451:
TOTAL REQUIRED END CAP LENGTH = HEIGHT X 2.
•
# OF END CAPS = TOTAL REQUIRED END CAP LENGTH / 84 + 1 (round up).
•
Example (above): Total required end cap length = 80 X 2 = 160. # of End Caps = 160/84 + 1= 2.905 = 3 pc.
•
5.
Sidesplash & backsplash calculations are the same.
4.
When hoods are ordered end to end, backsplash should be ordered under hood #1.
3.
Divider bars (part # J64-1450)are used to cover raw edges between adjacent panels.
2.
End caps (part # J63-1451) are used to cover raw edges on ends of backsplash sections.
1.
Vertically installed backsplash is always used on height requirements over 48".
Ordering Notes:
Equal Panel Length Option: # OF PANELS (ROUND UP) = TOTAL LENGTH / W (W = Max Panel Width*). INDIVIDUAL PANEL WIDTH (NON-INSULATED) = (TOTAL SECTION
•
LENGTH - 1/16 x (# OF PANELS - 1)) / # OF PANELS. INDIVIDUAL PANEL WIDTH (INSULATED) = TOTAL SECTION LENGTH / # OF PANELS.
Equal Panel Length Example (above): # of Panels = 250/48 = 5.208 = 6 (round up). Individual panel width = (250 - 1/16 x 5) / 6 = 41.615 (non-insulated)
•
Calculating Back & Side Splash:
# OF FULL PANELS (round down)= TOTAL SECTION LENGTH / W, (W = Max Panel Width*)
•
LAST PANEL WIDTH = REMAINDER x W (for non-insulated backsplash, subtract 1/16" x #of divider bars from last panel width to compensate for divider bar width).
•
If width of last panel is less than 20", transfer 12" from second to last panel to last panel. Transfer additional 6" if last panel is still less than 20".
•
Example (above): # of Full Panels = 250 / 48 = 5.208 = 5 (round down). Width of remaining panel = 0.208 x 48 - 5/16 = 9-11/16, add 12 for final panel width of 21-11/16.
•
Panel widths will be 4 panels at 48", 1 panel at 36", 1 panel at 21-11/16".
Calculating # Of Divider Bars - Part # J64-1450:
TOTAL REQUIRED DIVIDER BAR LENGTH = (# PANELS - 1) x HEIGHT.
•
*MAX PANEL SIZE FOR VERTICAL BACK SPLASH
Uninsulated = 48" X 192"
1" Insulated = 45" X 190"
3" Insulated = 41" X 186"
J63-1451 End Cap
J63-1451 End Cap
J64-1450 Divider Bars
J64-1450 Divider Bars
Top of back splash
is covered by the hood.
Back Splash
Side Splash
Inside Corner
80.000
250.000
58.000
102.000