Ldvr series direct vent gas fireplace, Framing and finishing, Gas inlet and manifold pressures – Vermont Casting 43LDVR User Manual

Page 6: Gas specifications

background image

6

LDVR Series Direct Vent Gas Fireplace

10007317

Noncombustible materials such as brick or tile may be
extended over the edges of the face of the fireplace.
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the fireplace.

Final Finishing

33LDVR / 36LDVR / 39LDVR / 43LDVR

Certified To

ANSI Z21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

Framing and Finishing

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Gas Inlet and Manifold Pressures

Natural

LP (Propane)

Check fireplace to make sure it is levelled
and properly positioned.

To mount the appliance:
1. Choose the location.
2. This unit comes with four (4) flanges pre-mounted

on both sides of the fireplace to allow two different
drywall thicknesses to be used. Flange “A” is for 1/2”
drywall while flange “B” is for 5/8” drywall.

3. Bend the desired flanges out 90° on both sides of

the fireplace. Slide the fireplace into the framed
opening until the flanges contact the front surfaces
of the framing. Level the unit and secure it firmly in
place.

FP1544

nail flange

1/05

Fig. 4 Nailing flanges.

Flange

Drywall

Position

Depth

A

1/2” / 13 mm

B

5/8” / 16 mm

Flange Location for

Desired Drywall Depth

FP1539

A

B

33LDVR units: GFRN2I0, GFRL2I0, GFRE2I0
36LDVR units: GFRN2J0, GFRL2J0, GFRE2J0
39LDVR units: GFRN2K0, GFRE2K0
43LDVR units: GFRN2N0, GFRE2N0

*Using conversion kit

Max.

Min.

Air

Gas

Input

Input

Shutter

Model

Fuel Control BTU/h BTU/h

Adj.

33LDVRRN

Nat Millivolt 16,000 11,200

3/16”

Open

33LDVRRP Prop Millivolt 16,000 12,000 Fully Open
33LDVREN

Nat

24V

16,000 11,200

3/16”

Hi/Lo

Open

33LDVREP Prop*

24V

16,000 12,000 Fully Open

Hi/Lo

36LDVRRN

Nat Millivolt 19,500 13,650

Top &

Bottom

Hole Half

Closed

36LDVRRP Prop Millivolt 19,500 14,625 Fully Open
36LDVREN

Nat

24V

19,500 13,650

Top &

Hi/Lo

Bottom

Hole Half

Closed

36LDVREP Prop*

24V

19,500 14,625 Fully Open

Hi/Lo

39LDVRRN

Nat Millivolt 23,000 16,100

Top &

Bottom

Hole Half

Closed

39LDVRRP Prop* Millivolt 22,500 16,875 Fully Open
39LDVREN

Nat

24V

23,000 16,100

Top &

Hi/Lo

Bottom

Hole Half

Closed

39LDVREP Prop*

24V

22,500 16,875 Fully Open

43LDVRRN

Nat Millivolt 26,000 18,200

Top &

Bottom

Hole Half

Closed

43LDVRRP Prop* Millivolt 24,000 18,000 Fully Open
43LDVREN

Nat

24V

26,000 18,200

Top &

Hi/Lo

Bottom

Hole Half

Closed

43LDVREP Prop*

24V

24,000 18,000 Fully Open

Hi/Lo

Gas Specifications