Energenics 150 Low Profile Lint Filter (Old) User Manual
Page 4

 
 
 
 
 
Important Installation Considerations
 
All Energenics Lint Collectors can be mounted indoors or outdoors. If it is mounted outdoors we 
recommend our Side Discharge or a field installed swept radius elbow (Gooseneck). Do not use 
a “China type” cap on the discharge. The Pressure transducer should be mounted on top of the 
filter to prevent condensation running down the tubes into the pressure switch located in the 
pressure input box. Also, mount the supplied air pressure gauge at the blowdown pipe on top of 
the filter. 
 
All solenoids should be mounted as practically close to the filter as possible, but always inside the 
building. This will allow most of the air and water (if equipped with optional Fire Control) piping to 
remain pressure charged for most efficient operation. 
 
Energenics supplies a reel of wire connected on one end to the Filter Control. In most cases the 
reel is long enough for most indoor installations. In rare situations the wire is not long enough and 
must be extended. This is not difficult, but make sure the wire extensions are properly marked for 
correct termination. 
 
The Filter Control box should be located in a position to be easily seen and in close proximity to 
personnel. In other words if the Filter Control is located outdoors, 20 feet in the air or in another 
room away from the laundry personnel, this would be the wrong location. 
 
Since the Filter uses compressed air it is important that the air receiver (if equipped) be located as 
close to the filter as possible. The longer the pipe runs the more restrictive. You will need to 
increase the pipe diameter if the run is very long. 
 
If the installation is a multi-dryer/multi-duct installation it may be necessary to use backdraft 
dampers to prevent lint backflow into the ducts of turned off dryers. Most dryers have them 
available as standard equipment or can be ordered to add on. 
 
After everything is mounted and utilities turned on press the manual blowdown button located on 
the side of the Filter control box and the rotor on the inside the lint filter should spin. Make sure 
that the air pressure at the filter starts out at 100 and ends at about 60 at the end of the blowdown 
cycle. If it is too low the rotor won’t turn. 
 
If the Filter is equipped with Fire Suppression the test button is on the inside of the Filter Control. 
It is on the inside to keep people from pushing the button as they walk by. When the button is 
pushed the strobe and siren will go on along with the water solenoid valve. The system operates 
for 5 seconds and turns off automatically. 
 
 
 
 
 
 
 
 
 
 
 
 