Warning and caution, Start up and operation instructions – Energenics 120 Low Profile Lint Filter (Old) User Manual
Page 6

 
 
 
 
Warning and Caution
You have purchased the finest lint filter available for your facility. Please follow these 
instructions to ensure a safe long life for your filter and facility. 
 
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN AN UNSAFE
OPERATING CONDITION, INCLUDING THE POSSIBILITY OF FIRE.
 
DO NOT OPERATE ANY DRYER CONNNECTED TO THIS FILTER 
WITHOUT BEING CERTAIN THE FILTER STARTUP HAS BEEN 
COMPLETED AND THE FILTER IS IN OPERATING CONDITION. 
Insure it is installed in compliance with local codes. 
Step 1. Install the compressed air (Fire suppression plumbing if ordered), and 
piping system(s) including solenoid valves. If the filter is in position, make all final 
connections. 
 
Step 2. Mount the 9002 control in a visible location on a solid vibration free
surface and connect all components.
 
Step 3. Provide dedicated electrical service to the transformer and test all 
 
systems.
 
Step 4. Install sheet metal and ducting. 
 
START UP AND OPERATION INSTRUCTIONS 
 
Inspect the filter installation. Is it complete? Review the entire installation requirements prior 
to startup. 
 
1. Verify the 9002 control wiring. 
 
2. Test the blow down cycle (push manual button on control). 
Watch the pressure gauge. It should start at 100psi and should not drop below 
80psi during the 6-10 second cycle. 
 
The rotor should turn 6-12 times during blow down. The rotor propulsion is adjustable by 
increasing the number of horizontal holes on the top horizontal portion of the rotor end. 
 
3. Review maintenance requirements and establish a regular PM schedule. 
 