Ecler HZA4-120F User Manual
Page 34
34
6.3. Technical characteristics
6.3. Características técnicas
6.3. Caractéristiques techniques
6.3. Technische Daten
Output power:
1% THD
10% THD
1
Channel
114
WRMS
@
88
145 WRMS @ 88
2 Merged Channels
195 WRMS @ 50
226 WRMS @ 50
3 Merged Channels
290 WRMS @ 32
348 WRMS @ 32
4 Merged Channels
356 WRMS @ 26
430 WRMS @ 26
Frequency
response
(-3dB)
30Hz
–
55
kHz
High pass filter 3
rd
order
Butterworth
70Hz
THD + Noise @ 1kHz Full power
<0.03%
typ.
0.2%
max.
Signal
Noise
Ratio
@
100V
>90dB
Channel
Crosstalk
@
1kHz/100V >90dB
Inputs:
Sensitivity
nom/Impedance
0dBV/>20k
Connectors
Terminal
block
(Symmetrical)
Outputs:
Connectors
Terminal
block
Indicators:
Power
Green
(ON),
Red
(Standby)
Signal
present
-35dB
Clip
Overload
Thermal
Merge
Remote control:
DC
0-10V/0.1A max
No
attenuation
0V
Full
attenuation
+10V
Connectors
Terminal
block
Auto power:
Threshold
>-30dB
aprox
Time
100
sec.
aprox
Mains voltage
Depending on your country. See characteristics in the back of the unit.
Power consumption:
pink
noise,
1/8
power
340VA
pink
noise,
1/3
power
470VA
Standby <3W
Dimensions:
Panel
482.6x88mm
Depth
(Handle
excluded) 392mm
Weight
13.60kg