beautypg.com

Operating instructions – ebm-papst W4E500-GM03-01 User Manual

Page 5

background image

Operating instructions

W4E500-GM03-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M4E110-GF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1300

1400

Power input / W

680

880

Current draw / A

3.0

3.88

Motor capacitor / µF

12

12

Capacitor voltage / VDB

450

450

Max. back pressure / Pa

150

100

Min. ambient temperature
/ °C

-40

-40

Max. ambient
temperature
/ °C

65

40

Maximum safe operating
speed / min

-1

1920
@ 55 °C

1920
@ 55 °C

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

32.5

28.5

32.5

Efficiency grade N

40

36

40

Power input P

e

/ kW

0.65

Air flow q

v

/ m³/h

5765

Pressure increase total p

sf

/ Pa

129

Speed n / min

-1

1315

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

16.8 kg

Size

500 mm

Surface of rotor

Coated in black

Material of terminal box

PC / ABS plastic

Material of blades

Press-fitted sheet steel blank, sprayed
with PP plastic

Material of wall ring

Sheet steel, galvanised and coated in
black plastic (RAL 9005)

Material of guard grille

Steel, coated in black plastic (RAL9005)

Number of blades

5

Direction of air flow

"V"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"F"

Humidity class

F4-1

Mounting position

Any

Condensate discharge
holes

On rotor and stator sides

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Electrical leads

Via terminal box, integrated capacitor
connected via terminal box

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 61800-5-1; CE

Approval

CSA C22.2 Nr.100; EAC; UL 1004-1;
VDE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10080-5-9970 · Revision 83181 · Release 2014-06-04 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com