3.2 Nominal data
Motor
M4E110-GF
Phase
1~
1~
Nominal voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
ml
ml
Valid for approval /
standard
CE
CE
Speed / min
-1
1300
1400
Power input / W
680
880
Current draw / A
3.0
3.88
Motor capacitor / µF
12
12
Capacitor voltage / VDB
450
450
Max. back pressure / Pa
150
100
Min. ambient temperature
/ °C
-40
-40
Max. ambient
temperature
/ °C
65
40
Maximum safe operating
speed / min
-1
1920
@ 55 °C
1920
@ 55 °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
32.5
28.5
32.5
Efficiency grade N
40
36
40
Power input P
e
/ kW
0.65
Air flow q
v
/ m³/h
5765
Pressure increase total p
sf
/ Pa
129
Speed n / min
-1
1315
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
16.8 kg
Size
500 mm
Surface of rotor
Coated in black
Material of terminal box
PC / ABS plastic
Material of blades
Press-fitted sheet steel blank, sprayed
with PP plastic
Material of wall ring
Sheet steel, galvanised and coated in
black plastic (RAL 9005)
Material of guard grille
Steel, coated in black plastic (RAL9005)
Number of blades
5
Direction of air flow
"V"
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 54
Insulation class
"F"
Humidity class
F4-1
Mounting position
Any
Condensate discharge
holes
On rotor and stator sides
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads
Via terminal box, integrated capacitor
connected via terminal box
Motor protection
Thermal overload protector (TOP)
brought out
Cable exit
Axial
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval
CSA C22.2 Nr.100; EAC; UL 1004-1;
VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 10080-5-9970 · Revision 83181 · Release 2014-06-04 · Page 5 / 11