3.2 Nominal data

Motor

M3G112-IA

Phase

1~

Nominal voltage / VAC

230

Nominal voltage
range / VAC

200 .. 277

Frequency / Hz

50/60

Type of data definition

ml

State

prelim.

Speed / min

-1

710

Power input / W

730

Current draw / A

3.2

Max. back pressure / Pa

100

Min. ambient temperature
/ °C

-25

Max. ambient
temperature
/ °C

50

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

Yes

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

43.7

28.6

32.6

Efficiency grade N

51.1

36

40

Power input P

ed

/ kW

0.68

Air flow q

v

/ m³/h

11680

Pressure increase total p

sf

/ Pa

84

Speed n / min

-1

715

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

20 kg

Size

800 mm

Surface of rotor

Coated in black

Material of electronics
housing

Die-cast aluminium, coated in black

Material of blades

Press-fitted, coated sheet steel blank,
sprayed with PP plastic

Material of mounting
ring

Steel, galvanised and coated in black
plastic (RAL9005)

Material of wall ring

Sheet steel, galvanised and coated in
black plastic (RAL 9005)

Number of blades

5

Direction of air flow

"A"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"B"

Humidity class

F4-2

Mounting position

Shaft horizontal or rotor on top; rotor on
bottom on request

Condensate discharge
holes

On the stator side

Operation mode

S1

Motor bearing

Ball bearing

Technical features

- Output 10 VDC, max. 10 mA
- Output 20 VDC, max. 50 mA
- Output for slave 0-10 V
- Operation and alarm display
- Direction of rotation selection counter-
clockwise / clockwise
- Input for sensor 0-10 V or 4-20 mA
- External 24 V input (programming)
- Alarm relay
- Integrated PID controller
- Motor current limit
- PFC, active
- RS485 MODBUS RTU
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Over-temperature protected
electronics / motor
- Line undervoltage / phase failure
detection

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Electrical leads

Via terminal box

Motor protection

Thermal overload protector (TOP) wired
internally

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 61800-5-1; CE

Approval

EAC

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

Item no. 53159-5-9970 · Revision 83042 · Release 2014-07-14 · Page 5 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com