Operating instructions – ebm-papst G3G200-GN18-01 User Manual
Page 8

Operating instructions
G3G200-GN18-01
Translation of the original operating instructions
4.2.4 Locked-rotor protection
Due to the locked-rotor protection, the start-up current (LRA) is
equal to or less than the nominal current (FLA).
4.3 Connection via plug
4.3.1 Establish supply connections
CAUTION
Electrical voltage
The device is a built-in component and features no electrically
isolating switch.
→ Connect the device to a suitable trigger device. Connect the
device only to circuits that can be switched off using an all-
pole disconnecting switch.
→ When working on the device, you must switch off the
system/machine in which the device is installed and secure
it from being switched on again.
; Check the PIN assignment of your connector.
; Connect the panel connector and mating connector.
; Ensure that the connector is locked in correctly.
Item no. 50131-5-9970 · Revision 72552 · Release 2010-11-12 · Page 8 / 12