Operating instructions – ebm-papst G3G200-GN18-01 User Manual

Page 8

background image

Operating instructions

G3G200-GN18-01

Translation of the original operating instructions

4.2.4 Locked-rotor protection

Due to the locked-rotor protection, the start-up current (LRA) is
equal to or less than the nominal current (FLA).

4.3 Connection via plug

4.3.1 Establish supply connections

CAUTION
Electrical voltage
The device is a built-in component and features no electrically
isolating switch.
→ Connect the device to a suitable trigger device. Connect the

device only to circuits that can be switched off using an all-
pole disconnecting switch.

→ When working on the device, you must switch off the

system/machine in which the device is installed and secure
it from being switched on again.

; Check the PIN assignment of your connector.
; Connect the panel connector and mating connector.
; Ensure that the connector is locked in correctly.