Operating instructions – ebm-papst R2E180-CG82-01 User Manual
Page 5
Operating instructions
R2E180-CG82-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M2E068-CF
Phase
1~
Nominal voltage / VAC
230
Frequency / Hz
50
Type of data definition
fa
Valid for approval /
standard
CE
Speed / min
-1
2530
Power input / W
68
Current draw / A
0.30
Motor capacitor / µF
2
Capacitor voltage / VDB
400
Capacitor standard
P0 (CE)
Min. back pressure / Pa
0
Min. ambient temperature
/ °C
-25
Max. ambient
temperature
/ °C
60
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Technical features
Mass
2.5 kg
Size
180 mm
Surface of rotor
Uncoated
Material of impeller
Sheet steel, stainless
Material of mounting
plate
Sheet steel, hot-galvanised
Number of blades
6
Motor suspension
Motor anti-vibration mounted on one side
via mounting plate
Direction of rotation
Counter-clockwise, seen on rotor
Type of protection
IP 44; Depending on installation and
position
Insulation class
"F"
Humidity class
F0
Mounting position
Any
Condensate discharge
holes
None
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) wired
internally
Cable exit
Variable
Protection class
I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11125-5-9970 · ENG · Revision 82891 · Release 2015-01-29 · Page 5 / 9