4.4 Connection screen

No.

Conn.

Designation

Colour

Function / assignment

CON10 L

black

Power supply 230 VAC, 50-60 Hz, for voltage range refer to rating plate

CON11 N

blue

Neutral conductor

CON12 PE

green/
yellow

Protective earth

1

GND

blue

GND - Connection for control interface

2

0- 10V PWM

yellow

Control input 0 - 10 V or PWM, electrically isolated

3

10V/ max 1.1mA red

Voltage output 10V/ 1.1mA, electrically isolated, not short-circuit-proof.

4

Tach

white

Tach output: open collector, 1 pulse per revolution, electrically isolated

Item no. 51200-5-9970 · Revision 80549 · Release 2014-05-08 · Page 7 / 10