Operating instructions – ebm-papst K1G200-AD37-02 User Manual
Page 5
Operating instructions
K1G200-AD37-02
Translation of the original operating instructions
3.2 Nominal data
Motor
M1G074-BF
Nominal voltage / VDC
48
Nominal voltage
range / VDC
36 .. 57
Type of data definition
fa
State
prelim.
Speed / min
-1
4140
Power input / W
183
Current draw / A
5.6
Max. back pressure / Pa
520
Min. ambient temperature
/ °C
-25
Max. ambient
temperature
/ °C
70
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
A
Efficiency category
Static
Variable speed drive
Yes
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual
Request
2013
Request
2015
Overall efficiency η
es
/ %
44.6
29.4
32.4
Efficiency grade N
62.2
47
50
Power input P
e
/ kW
0.21
Air flow q
v
/ m³/h
700
Pressure increase total p
sf
/ Pa
430
Speed n / min
-1
4070
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
1.7 kg
Size
200 mm
Surface of rotor
Coated in black
Material of impeller
Plastic PA6, fibreglass-reinforced
Housing material
Plastic PA6, fibreglass-reinforced
Material of support
bracket
Plastic PA6, fibreglass-reinforced
Number of blades
7
Direction of air flow
"V"
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20; Depending on installation and
position
Insulation class
"B"
Humidity class
F0
Mounting position
Any
Cooling bore / aperture
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Technical features
- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM
Motor protection
Reverse polarity and locked-rotor
protection
Cable exit
Lateral
Product conforming
to standard
EN 60950-1
Approval
CSA C22.2 Nr.77; EAC; UL 1004-1
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
3.7 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2 (industrial
environment)
EMC interference
emission
Acc. to EN 55022 (Class B)
Item no. 50899-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com