beautypg.com

Operating instructions – ebm-papst K1G200-AD37-02 User Manual

Page 5

background image

Operating instructions

K1G200-AD37-02

Translation of the original operating instructions

3.2 Nominal data

Motor

M1G074-BF

Nominal voltage / VDC

48

Nominal voltage
range / VDC

36 .. 57

Type of data definition

fa

State

prelim.

Speed / min

-1

4140

Power input / W

183

Current draw / A

5.6

Max. back pressure / Pa

520

Min. ambient temperature
/ °C

-25

Max. ambient
temperature
/ °C

70

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

Yes

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

44.6

29.4

32.4

Efficiency grade N

62.2

47

50

Power input P

e

/ kW

0.21

Air flow q

v

/ m³/h

700

Pressure increase total p

sf

/ Pa

430

Speed n / min

-1

4070

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

1.7 kg

Size

200 mm

Surface of rotor

Coated in black

Material of impeller

Plastic PA6, fibreglass-reinforced

Housing material

Plastic PA6, fibreglass-reinforced

Material of support
bracket

Plastic PA6, fibreglass-reinforced

Number of blades

7

Direction of air flow

"V"

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20; Depending on installation and
position

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Cooling bore / aperture

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM

Motor protection

Reverse polarity and locked-rotor
protection

Cable exit

Lateral

Product conforming
to standard

EN 60950-1

Approval

CSA C22.2 Nr.77; EAC; UL 1004-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.

by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

3.7 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2 (industrial
environment)

EMC interference
emission

Acc. to EN 55022 (Class B)

Item no. 50899-5-9970 · ENG · Revision 83494 · Release 2014-10-16 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com