OPERATING ACCURACY:
0.1% of Capacity.
REPEATABILITY:
0.02% of Capacity.
LOAD CELLS:
4 stainless steel strain gage shear beams, 350 ohms.
SIGNAL CABLE:
15' of 6 conductor color coded shielded cable. PVC jacket.
SECTION 7.0 SPARE PARTS LIST
PART DESCRIPTION
MODEL/CAPACITY
INH P/N
S.S. Load Cell
C3600P / 3,000#
500337
S.S. Load Cell
C7200P / 5,000#
500088
S.S. Stop Rod
C3600P / C7200P
400186
S.S. 1/2-20 Hex Nut
C3600P / C7200P
615006
S.S. 1/2 Flat Washer
C3600P / C7200P
615007
S.S. 1/2 Lock Washer
C3600P / C7200P
615008
S.S. 1/2-20 X 1 3/4 S.H.C.S. Mounting bolt
C3600P / C7200P
615003
Shock Pad (2" X 1.5" X .75")
C3600P / C7200P
400014
Plastic Roller
C3600P / C7200P
400132
S.S. Roller Axle
C3600P / C7200P
400022
S.S. Retaining Ring
C3600P / C7200P
670131
Plastic Plug
C3600P / C7200P
650020
15' of 6 Conductor Cable
C3600P / C7200P
500061
Summing Box SJB-4-S (complete)
C3600P / C7200P
110143
Summing Board only SJB-4-S
C3600P / C7200P
110048