Meter wiring

The “A-MTR” feed is a buffered output designed to drive the VU meters and

headphone amp in the MQ metering and cue box. The feed can also drive a standard VU

meter circuit. The Monitor’s D/A is calibrated so that a digital sine wave of 1 kHz

frequency at -14dBfs will provide a +4dBu signal level. Calibration tones are available

from the oscillator in the DAW or a test CD.


Standard VU meter circuit

The selected Digital Input to be monitored is fed to the “D-MTR” XLR on the rear panel.

This output is a standard AES digital output that goes to MQ’s AES input or another

digital meter or phase scope.

Interface


The following section is intended to help installers set the system up for quiet,

dependable operation. If trouble is encountered setting up the Monitor, the suggestions
may help in understanding the issues and resolving the problems. The techniques
discussed while not infallible, have been used for many years by the engineers at
Dangerous Music with a fantastic success rate setting up dozens of world class facilities.