Power Up the Equipment

Step 1

If you are using the redundant-with-reboot configuration (not recommended), power up the switch by connecting the
AC power cord of the hub or switch to an AC power outlet.

Note

If you use the redundant-with-reboot configuration, it is important to power up the hub or switch before powering up
the Cisco RPS to ensure correct operation. If the Cisco RPS powers up first, the LEDs might not indicate the actual
state.

Step 2

Plug the other end of the Cisco RPS AC power cable into an AC power outlet.

Step 3

Power up the Cisco RPS. There is a separate power switch for each AC input power source. Make sure that the power
switch is on for each AC power source used. (See Figure 17.)

Figure 17

Powering Up the Cisco RPS

The Cisco RPS provides power in 10 to 15 seconds. The Cisco RPS is working properly when all its front-panel LEDs are solid
green. If the external device does not power up, refer to troubleshooting section of the Cisco Redundant Power System
Hardware Installation Guide
on Cisco.com.

6

Obtaining Documentation

Cisco provides several ways to obtain documentation, technical assistance, and other technical resources. These sections explain
how to obtain technical information from Cisco Systems.

Cisco.com

You can access the most current Cisco documentation on the World Wide Web at this URL:

http://www.cisco.com/univercd/home/home.htm

You can access the Cisco website at this URL:

http://www.cisco.com

International Cisco websites can be accessed from this URL:

http://www.cisco.com/public/countries_languages.shtml

29091

Power switch