sit for extended periods of the time after sanitiza-

tion.

1

Before starting the procedure described

below wash hands with an anti-bacterial soap.

2

Prepare at least. four litres of hot water (45-

60°C, 113-140F) and sterilising product legally

approved in your Country, following the instruc-

tions of the manufacturer. If there is no specific

sterilising product prepare a solution of water

and bleach in the following ratio: 1 tbsp: 2 litres

(0.5gal) of water.

3

Immerse all the parts to be sterilised in the

solution for time indicated by the manufacturer.

4

Allow the sterilized parts to air dry on a clean

surface.

5

Use non-abrasive cloths to dry the external

parts.

6. 4 ASSEMBLY
1

Put the drip-tray and grill in place.

2

Lubricate the faucet piston (in the area A

shown in fig. 2) using food grade approved lubri-

cant.

figure 2

3

Reassemble the faucet assembly on the con-

tainer in the opposite way to which it was

dismantled (see fig. 1).

4

Install the container putting the central shaft

in place.

5

Insert the mixer in the central shaft.

6

Position the cover on the container.

7 MAINTENANCE

1

Daily: check the dispenser for any loss of

product from the gaskets. If there is, first check

the dispenser is assembled correctly making

sure that the gaskets need no lubricating and

they are not faulty or worn. In this case they must

be replaced with original parts.

2

To avoid damage to the dispenser the plastic

parts must be lubricated only with the grease

supplied by the manufacturer or other grease

compatible with polycarbonate.