9
Up and Down Switching
•
To lift a load, press ↑ button and drum will rotate as shown below operation.
•
To lower a load, press ↓ button and drum will rotate as shown below.
•
To stop hoisting, release ↑or ↓ button.
•
To have an emergency stop function, press the emergency stop button (option). Rotate
the button clockwise for returning.
Wire Rope Replacement
•
A minimum of five (5) wraps of rope around the drum is necessary to support the load rated.
•
Perform the daily inspection of the wire rope.
•
Replace the wire rope immediately if it is kinked, rusty, deformed, or having broken wires
or burrs.
•
Replace only with new rope of correct size , length and strength to safety handle the load.
•
Insert the wire rope into the hole of drum and fix it with a P.T. screw
•
Press ↑ button to wind the drum.
Carbon Brush Replacement
•
Always replace the brushes in pairs.
•
Brushes worn left below 7.5mm in length shall be replaced immediately.
•
Any negligence of replacement of it may cause damage to motor.
•
Avoid water splashes on the motor.
•
Remove the brush cap and replace it accordingly.