beautypg.com

Specifications, Unpacking, Operation – Harbor Freight Tools AIR STAPLER 40072 User Manual

Page 7

background image

Page 7

For technical questions, please call 1-800-444-3353.

SKU’s 40072,

40073, & 97521

SPECIFICATIONS

Operating

Pressure

60-100 PSI

Staple Capacity 80
Staple Length /

Type

3

/

4

” to 1-

1

/

2

”,

1

/

4

” Crown,

.039-.042” Shank (18 Gauge)

Air Inlet

1

/

4

” NPT (18 TPI - male/female

adapter included)

Note: SKU’s 40072 and 97521 contain the

Stapler by itself.

SKU 40073 contains the Stapler,

pneumatic tool oil, 2 hex wrenches, and

a blowmold carrying case.

UNPACKING

When unpacking, make sure the item

is intact and undamaged. If any parts are

missing or broken, call Harbor Freight Tools at

1-800-444-3353 as soon as possible.

OPERATION

For best service, incorporate an oiler,

regulator, and inline filter, as shown in the

diagram below. Hoses, couplers, oilers,

regulators, and filters are all available at

Harbor Freight Tools.

Quick

Coupler

Recommended Air Line Components

Regulator with

Pressure Gauge

Quick

Coupler

Air Hose

on Reel

Valve

Filter

Oiler

Coupler

Plug

Tool

Air

Compressor

Coupler

Plug

Note: To connect this tool, we recommend

a quick coupler/adapter (not included).

Coupler/adapters are available at Harbor

Freight Tools. For smoother operation,

put 3-5 drops of pneumatic tool oil in the

Air Plug (82) before each use.

Testing the Single Sequential Safety

Trip Mechanism

Warning: Even though the Stapler should

be empty during this procedure,

ALWAYS point the Stapler at a piece

of scrap wood when testing.

1. Make sure the tool is disconnected from

the power supply.

2. Completely empty the magazine of

staples.

3. The Stapler should not fire if the nose is

not depressed against the workpiece.

4. Check that the Trigger (39) and the

Safety (52) move freely, without sticking.

5. Connect the air supply to the tool at the

Air Plug (82) set at the recommended

60-100 PSI, and not to go over the

maximum 100 PSI.

6. Test the tool by depressing the Safety

(52) against the workpiece without

pulling the Trigger (39).

The tool must

not cycle (fire). If it cycles (fires),

stop immediately and take the tool to a

qualified service technician.

7. Hold the tool away or off of the

workpiece. The Safety (52) of the tool

should return to its original position.

Squeeze the Trigger (39).

The tool

should not cycle (fire). If it cycles

(fires), stop immediately and take the

tool to a qualified service technician.

8. Depress the Safety (52) against the

workpiece and squeeze the Trigger (39).

The tool must cycle (fire) once only.

Release the trigger and squeeze it again.

The tool must cycle (fire) once only.

REV 10a