HVH-TK-5 Components KiT
HVH-TK-6 Components Kit
Part Number*
Part Number*
Thermostat
300-049197-003
300-049197-004
Screws
248-049282-021 (2)
248-049282-021 (2)
Rubber Grommet
135-075436-008
135-075436-008
Label Decal
170-049279-016
170-049279-016
Bulb Clip
059-075500-002
059-075500-002
Knob
169-049278-001
169-049278-001
*Number in Parentheses ( ) indicates the quantity of that part required.
2150 N. RULON WHITE BLVD., OGDEN, UT 84404
Phone: 1-800-368-2493 www.chromalox.com
T A - U 0 - E F
Litho in U.S.A.
RENEWAL PARTS IDENTIFICATION
RENEWAL PARTS IDENTIFICATION
Figure 8
1Ø or 3Ø with optional external 24
or 120V control using double
pole thermostat
TO T1
TO T1
TO T2
TO T3
TO T3
TO T2
{
{
Remove jumper wire when
thermostat is used
Motor
Elements
3Ø Wiring
Terminal
Block
T1
T3
T2
L1
L3
L2
C1
C2
C3
1Ø Wiring
To T1 To T1 To T1
To T2 To T2 To T2
Optional
Disconnect
Switch Built
in or field
installed
Power
60 Hz
Optional Double
Pole Thermostat
Cutout
Externally Provided Control Voltage.
See Nameplate for Voltage.
NOTE:
1. Omit "L3" wiring for 1Ø heaters