beautypg.com

Replacement parts, Performance data – Culligan US-640 User Manual

Page 5

background image

NOTE: Substances reduced are not necessarily in your water. Filter must be maintained
according to manufacturer’s instructions, including replacement of filter cartridges.

WARNING:

Do not use with water that is microbiologically unsafe or of unknown

quality without adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may contain filterable cysts.
Contact your area retailer or local water treatment professional for replacement cartridge
pricing.
Suggested Retail Price for Replacement Filter Cartridges: D-40 $39.99

Test Conditions

Operating Requirements

Flow Rate

= 0.6 gpm

Pressure

= 30–125 psi (2.1-8.6 bar)

Inlet Pressure= 60 psi (4.1 bar)

Temperature = 40–100°F (4.4–37.8°C)

pH

= 7.5 ± 1

Turbidity

= 5 NTU Max.

Temperature = 68°F ± 5°F (20°C ± 2.5°C)

2

1

3

4

11

10

9

5

8

6

7

12

Replacement Parts

1

144802

Pressure-Relief Assembly

2

154530

White Cap

3

143338

Screws for Mounting Bracket

4

151231

O-ring (OR-233)

5

155466

D-40 Filter Cartridge

6

153126

White Housing

7

150424

Housing Wrench (SW-5)

8

151242

Lead-Free Faucet (FT-10)

9

143209

Quick-Connect Tee

10 143410

Quick-Connect Union

11 144805

Quick-Connect Faucet Adapter

12 144097

Clear 3/8-inch Tubing

For replacement parts, contact your nearest retailer or callCulligan Consumer Services at 1-888-777-7962.

Performance Data

Model US-640

Important Notice: Read this performance data and compare the capabilities of this system
with your actual water treatment needs. It is recommended that, before installing a water
treatment system, you have your water supply tested to determine your actual water treat-
ment needs.
This system has been tested according to NSF/ANSI 42 and 53 for reduction of the sub-
stances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42 and 53.

D-40 Cartridge

Substance

Influent Challenge Max. Permissible Product Reduction

Minimum

Average

Concentration

Water Concentration Requirements

Reduction

Reduction

Standard 42 Aesthetic Effects
Chlorine

2.0 mg/L ± 10%

≥ 50%

97%

Particulates at least 10,000 particles/mL

≥ 85%

96%

(0.5 to < 1µm) Class I

Standard 53 Health Effects
Cysts

2)

Minimum 50,000/L

99.95%

99.99%

99.99%

Turbidity

11 ± 1 NTU

0.5 NTU

99.1%

99.4%

Asbestos

10

7

to 10

8

fibers/L >10

99%

99.9%

99.9%

Micrometers in length

Lead 6.5 pH

0.15 mg/L ± 10%

0.010 mg/L

99.3%

99.3%

Lead 8.5 pH

0.15 mg/L ± 10%

0.010 mg/L

94.1%

97.6%

Mercury 6.5 pH 0.006 mg/L ± 10%

0.002 mg/L

85%

90.8%

Mercury 8.5 pH 0.006 mg/L ± 10%

0.002 mg/L

80.6%

90%

Atrazine

0.009 mg/L ± 10%

0.003 mg/L

89%

89%

Lindane

0.002 mg/L ± 10%

0.0002 mg/L

92.4%

92.4%

Flow Rate = 0.6 gpm (2.27 L/min)

Capacity = 600 gallons (2271 L) or 6 months

2)

Based on the use of microspheres

Testing was performed under standard laboratory conditions, actual performance may vary.