beautypg.com

General troubleshooting – Chauvet 700 User Manual

Page 10

background image




Page 10 of 12

Hurricane™ 700 User Manual (Rev. 08)

General Troubleshooting

Symptom

Possible Cause

Possible Action

Circuit breaker
or fuse keeps
blowing

 Excessive load on the circuit

 Make sure that the total load

does not exceed 80% of the
breaker or fuse nominal current

 Short circuit along the power

lines

 Check the power lines and

power cords

Product does not
power up

 No energy on power outlet

 Check power outlet
 Change to another outlet

 Loose or damaged power cord

 Check the power cord

 Blown

fuse

 Replace blown fuse with a good

one of the same type and rating

 Internal

problem

 Send product for repair

If you still experience problems after trying the above solutions, contact
CHAUVET® Technical Support.