ELECTRICAL REQUIREMENTS
OBSERVE ALL LOCAL CODES AND ORDINANCES,
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE
THE POWER SUPPLY CORD GROUND PRONG.
ELECTRICAL GROUND IS REQUIRED ON THIS
APPLIANCE.
For 230/208 voli 60 Hz, AC only, 15A fused and
properly grounded electricaf supply is required, A time
delay fuse or time delay circuit breaker is
recommended. Use a dedicated circuit, serving only
this appliance.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be grounded.
This appliance has a power supply cord with a 3-prong
grounding plug. To minimize possible shock hazard, the
cord must be plugged Into a mating grounding type wall
receptacle and grounded in accordance with the National
Electrical Code (ANSi/NFPA 70) latest edition and all local
codes and ordinances. If a mating wall receptacle is not
available, it is the personal responsibility and obligation of
the customer to have a properly grounded 3-prong wall
NOTE: The shape may be different according to its model
Use Wall Receptacle
Power Supply
Standard 125V,
/1 1 \ 3-wire grounding
\
0
/ receptacle rated
15A, 125VAC
Use 15 AMP. time
delay fuse or 15 AMP
circuit breaker.
Standard 250V,
7^ 3-wire grounding
\ »
7
receptacfe rated
15A, 250VAC
/W" Standard 250V,
1
1 3-wire grounding
1
_ / receptacle rated
20A, 250V AC
Use 20 AMP. time
delay fuse or 20 AMP
circuit breaker.
A
warning
%r
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
INSTALLING THE POWER CORD
You can choose between the two methods below according to your preference and window sill shape.
USING SLIT "A"
Fasten the stopper using Type A screw, and lead the
power cord out through slit "A".
Screw (Type A)-
Po'wer card
USING SLIT "B"
Fasten the stopper using left screw hole, and rotate