Troubleshooting Guide
Start Up Conditions
CONDENSATION
Whenever the water heater is filled with cold water, a certain
amount of condensation will form while the burner is on. A
water heater may appear to be Icakine when in fact the water is
condensation. This usually happens when:
• When a new water heater is filled with cold water for the
first time.
•
When gas burns and water vapor is produced in water
heaters, particularly high efficiency models where flue tem
peratures are lower.
• When you use large amounts of hot water, in a short time
and the refill water is very cold.
Moisture from the products of combustion condense on the
cooler tank surfaces and form drops of water which may fall
onto the burner or other hot surfaces to produce a “sizzling” or
“frying” noise.
Excessive condensation can cause pilot outage due to water run
ning down the flue tube onto the main burner and putting out
the pilot.
Because of the suddenness and amount of water, condensation
water may be diagnosed as a “tank leak”. After the water in the
tank warms up (about 1-2 hours), the condition should
disappear.
Do not assume the water heater is leaking until there has been
enough time for the water in the tank to warm up.
An undersized water heater will cause more condensation. The
water heater must be sized properly to meet the family’s
demands for hot water including dishwashers, washing machines
and shower heads.
Excessive condensation may be noticed during the winter and
early spring months when incoming water temperatures are at
their lowest.
Good venting is essential fot a gas fired water heater to operate
properly as well as to carry away products of combustion and
water vapor.
SMOKE/ODOR
It is not uncommon to experience a small amount of smoke and
odor during the initial start-up. This is due to burning off of oil
from metal pans, and will disappear in a short while.
THERMAL EXPANSION
Water supply systems may, because of high line pressure, fre
quent cut-offs, the effects of water hammer and others, have
installed devices such as ptessure reducing valves, check valves,
back flow preventers, etc. to control these types of problems.
When these devices are not equipred with an internal by-pass,
and no other measures arc taken, the devices cause the water sys
tem to be closed. As water is heated, it expands (thermal expan
sion) and closed systems do not allow for the expansion of heat
ed water.
The water within the water heater tank expands as it is heated
and increases the pressure of the water system. If the relieving
point of the water heaters temperature-pressure relief valve is
reached, the valve will relieve the excess pressure. The tempera
ture-pressure relief valve is not intended for the constant
relief of thermal expansion. This is an unacceptable condition
and must be corrected.
It is recommended that any devices installed which could create
a closed system have a by-pass and/or the system have an expan
sion tank to relieve the pressure built by thermal expansion in
the water system. Expansion tanks ate available for ordering
through the Sears Service Center. Contact the local plumbing
inspector, water supplier, and/or the Sears Service Center for
assistance in controlling these situations.
Thermal Expansion Tank Specifications
Model
Tank Capacity
In Gallons
Dimensions in Inches
Pipe Fitting
Number
Diameter
Length
On l ank
153.331020
2
8 inches
125^4 inches
V"
Male
153.331050
5
11 inches
14)4 inches
y,"
Male
AWARNING
HOTTER WATER CAN SCALD: Water heaters are intended to
produce hot water. Water heated to a temperature which will
satisfy clothes washing, dish washing, and other sanitizing needs
can scald and permanently injure you upon contact Some peo
ple are more likely to be permanently Injured by hot water than
others. These include the elderly, children, the infirm, or physicab
ly/mentally handicapped. If anyone using hot water in ywjr home
fits into one of these groups or if there is a local code or state law
requiring a certain temperature water at the hot water tap, then
you must take special precautions. In addition to using the lowest
possible temperature setting that satisfies your hot water needs,
a means such as a mi»ng valve, should be used at the hot water
taps used by these people or at the water heater. Mixing valves
are available at plumbing supply or hardware stores. Follow man
ufacturers instructions for installation of the valves. Before
changing the factory setting on the thermostat, read the
‘Temperature Regulation” section in this manual.
Expansion Tank Sizing Chart
Expansion
Tank
Capacity
Needed
Inlet*
Water
Pressure
Water Heater Capacity (Gallons)
30
40
50 ;
66
82
40 psi
2
2
2
5
5
50psi
2
2
2
5
5
60psi
2
2
5
5
5
70psi
2
2
5
5
5
SOpsi
2
5
5
5
5
*Highesc recorded inlet water pressure in a 24 hour period or
regulated water pressure.
NOTE; Expansion tanks are pre-charged with a 40 psi air
charge. If the inlet water pressure is higher than 40 psi, the
expansion tank’s air pressure must be adjusted to match that
pressure, but must not be higher than 80 psi.
22