Installation checklist, Check for leaks, Installation instructions (cont’d) – Kenmore POWER MISER 153.330751 User Manual
Page 16
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
VENT PIPE TO
OUTDOORS
OR CHIMNEY
Installation Checklist
BEFORE LIGHTING THE PILOT:
• Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for gas leaks
using a match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
flttin».
c. Check for bubbling soap. This means you have a teak.
Turn “OFF” gas and make the necessary repairs.
d. Rccheck for leaks.
e. Rinse off soapy solution and wipe dry.
• Is the new temperature-pressure relief valve properly installed
and piped to an adequate drain? See “Temperature-Pressure
Relief Valve” section.
-
•
Are the cold and hot water lines connected to the water
heater correctly? See “Water Piping” instructions in the
“Installation Instructions” section.
• Is the water heater completely Ailed with water? See “Filling”
instructions in the “Installation Instructions”.
•
Will a water leak damage anything? See the “Facts to
Consider About the Location” section.
•
Is there proper clearance between the water heater and any
thing that might catch fire? See the “Facts to Consider About
the Location” section.
•
Do you have adequate ventilation so that the water heater
will operate properly? See “Combustion Air and Ventilation”
in the “Facts to Consider About the Location” section.
•
Is the draft hood vent piping properly secured? See “Venting”
instructions in the “Installation Instructions” section.
•
Is there proper clearance between the vent pijie and anything
that might catch on fire? See “Venting” instructions in the
“Installation Instructions” section.
•
Is the vent pipe properly sloped and does the vent terminate
outdoors? See ' Venting” instructions in the “Installation
Instructions" section.
•
Do you need to call your gas company to check the gas pipe
and its hookup?
Installation Instructions (cont’d)
CHECK FOR LEAKS
Be sure to check all your gas pipes for leaks before lighting your
water hearer. Use a soapy water solution, not a match or open
flame. Check the factory^ fittings after pilot is lit and gas con
trol knob is still in “PILOT” position. Then, check the fittings
when the main burner is turned “ON”. Use a soapy water solu
tion for this, too.
>
\ COLD
UNION SHUTOFF VALVE
DISCHARGE PIPE
(Do not cap or plug)
SHUTOFF .
valve
vfl
TEE
DRIP LEG
(SEDIMENT
TRAP)
6
INCH AIR GAP
-AumMTK ePORpei
water
heatert
MOM. NUMBER
CAP«rTY
1
1
water
HEATER
■QUPPS
PÛR MPUT
ttCOVERY
UAQAL
aSNM. HUWêÉR
1
1
1
QA8 BTUWL
MMOMUM HYDROBTA'nC
lllMWPII 1 iilllN
QN
j
MR.
9A8
PResSUne IN W.C.
HM.IUT laM. BUT NICaUH
hmiiwui
150 j
1 1
PAJ.
WA.
WA. WÆ.
MODEL RATING PLATE
16