Service Tech Information
TROUBLESHOOTING
VALVE POSITION INDICATORS:
Depending on the valve position, the following indica
tors show in the display:
Indicator
Valve Position
Serv
........................................ Service
Fill
........................................... Fill
Brine
....................................... Brining/Brine
Rinse
Bkwsh
.....................................Backwash
Rinse
...................................... Fast Rinse
When the valve is rotating from one cycle to another,
both indicators flash. For example, if the valve is in
transition between fill and brining, both Fill and Brine
flash. Upon reaching brining position. Fill goes off and
Brine is on steady. The time display shows the minutes
of the cycle remaining.
NOTE: If the
faceplate
is left in a diagnostic display
(or a flashing display when setting times or hard
ness), present time automatically returns if a button
is not pressed within 4 minutes. To return to the
diagnostic display, repeat step 1.
OTHER INFORMATION
While in this diagnostic screen, the following information
is available and may be beneficial for various reasons.
This information is retained by the computer from the
first time electrical power is applied to the faceplate.
• Press and hold the UP button to display the number of
days this faceplate has had electrical power applied.
• Press and hold the DOWN button to display the num
ber of regenerations initiated by this faceplate since
the code number was entered.
• Press the RECHARGE button to advance the valve to
each position and observe the switch and position
indicators to verify component operation, or to possi
bly isolate a defect.
• Press and hold the SELECT1 button for 3 seconds
until a model code shows in the display, see Fig. 64.
This code identifies the softener nominal capacity
size. If the wrong number shows, the softener will
operate on incorrect data. Do the following as needed.
If the correct model code (H 32) shows:
Press the
SELECT1 button to return to the present time display.
To change the number:
Press the UP or DCWN but
ton until the correct model code (H 32) shows. Then,
press the SELECT1 button and reset the timer.
Valve Outlet
FIG. 62
TIMER PWA REPLACEMENT
Be sure the valve is in service position when replac
ing the timer PWA (observe valve cycle indicator). If
after installing and programming the replacement timer
PWA, the valve is not in service position, do the following
to assure correct cycle orientation, or timing, between the
faceplate and valve.
Use the MANUAL ADVANCE procedures with the
RECHARGE
NGW button, advance through the recharge
cycles until the valve stops in service position, and
RECHARGE no longer flashes in the display.
NOTE: The valve motor may automatically drive
through several valve positions while searching for
service. If an error code occurs, unplug the trans
former, then plug in again.
FIG. 64