Facts to consider about the location, A caution, A warning – Kenmore Power Miser 12 153.320493 HT User Manual
Page 7: Installation instructions (contad)
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Installation Instructions (contad)
Facts to Consider About the
Location
You
should
carefully
choose
an
indoor
location
for
the
new
water heater, because the placement is a very important consid
eration for the safety of the occupants in the building and for
the most economical use of the appliance. This water heater is
not intended for outdoor installation.
Whether
replacing
an
old
water
heater
or
putting
the
water
heater in a new location, the following critical points must be
observed.
• The location selected should be indoors as close to and as
centralized
with
the
water
piping
system
as
possible.
This
water heater, as well as all water heaters, will eventually leak.
Do
not
install
without
adequate
drainage
provisions
where
water flow will cause damage.
A CAUTION
WATER
HEATERS
EVENTUALLY
LEAK:
Installation
of
the water heater must be accomplished in such a manner
that if the tank or any connections should leak, the flow of
water will not cause damage to the structure. For this
reason, it is not advisable to install the water heater in an
attic or upper floor. When such locations cannot be avoid
ed, a suitable drain pan should be installed under the
water heater. Drain pans are available at your local Sears
stores. Such a drain pan must be piped to an adequate
drain. Under no circumstances is the manufacturer or
Sears to be held liable for any water damage in connec
tion with this water heater.
A CAUTION
INSTALLATION
IN
RESIDENTIAL
GARAGES;
The
water heater must be located and/or protected so it is
not subject to physical damage by a moving vehicle.
The
location
selection
must
provide
adequate
clearances
for
servicing and proper operation of the water heater.
Facts to Consider About The
Convertible Lower Element
The Upper Element (if a double element model), is a conven
tional
3800
watt
element
which
only
operates
at
its
rated
wattage on 240 volts. (See rating plate on water heater).
The Lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.
Read and follow water heater warnings and instructions. If after
reading these instructions in this manual, if you do not under
stand any portion, call Seats Service Center,
A WARNING
Before making the conversion to 5500 watts, check the
(I) power supply...must be 240 volts, (2) wiring... 10 gauge
AWG, Type TW, 60*C or equivalent, and (3) Circuit
breakers or fusing...capable of 30 amp loading. Also, the
installation must conform with this manual, local codes
and electric utility rules. Failure to comply can result in
DEATH,
SERIOUS
BODILY
INJURY,
OR
PROPERTY
DAMAGE.
NOTE: Whether or not the element conversion is made the
model rating plate must be marked. Using a hard point ink
pen, check the appropriate block within the model rating
plate, which is located adjacent to the lower access panel.