CARE OF YOUR REVERSE OSMOSIS SYSTEM
REVERSE OSMOSIS SYSTEM CARE GUIDE
MODEL NO. 625.385750
1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges or when yellow LED flashes.
2. Replace the RO membrane cartridge when the percent rejection of total dissolved solids (TDS) is less than shown
in the specifications (see B, below) or when red LED flashes.
3. Replace the batteries once per year.
If any of the following occur before the 6 months, replace as directed.
A. Slow Making of Product Water:
Replace the prefilter cartridge.
If the production rate does not improve, replace the post filter car
tridge and RO membrane cartridge.
C. Chlorine Taste and/or Odor:
Replace the prefilter, post filter and
RO membrane cartridges.
B. High Total Dissolved Solids (TDS) in Product Water:
You can
get a free TDS test through some Sears retail stores or service
departments. If the store or service department does not have a
TDS meter, you can send treated and untreated water samples to
a water analysis lab for testing. It Is important to test both the
treated and untreated water to determine system performance. If
the TDS is not within the system’s performance guidelines,
replace the prefilter, post filter and RO membrane cartridges.
OTHER TROUBLESHOOTING
PROBLEM
CAUSE
CORRECTION
Chlorine taste and/or
odor
in the RO product
water
The ppm of chlorine in your water supply
exceeds maximum limits, and has de
stroyed the RO membrane.
If the water supply contains more than 2.0 ppm of chlorine, addi
tional filtering of the water supply to the RO is needed. Correct
this condition before doing maintenance on the RO system.
Replace the prefilter, post filter and RO membrane cartridges.
The prefilter is no longer removing chlo
rine from the water supply.
Other taste and/or odor
Post filter expended.
Replace the post filter cartridge. If taste and odor persists, re
place the prefilter cartridge and RO membrane cartridge.
RO membrane cartridge expended.
Contamination in product water storage.
Use sanitizing procedures. Replace the post filter cartridge.
System makes product
water too slowly
Water supply to the RO system not within
specifications.
Increase water pressure, precondition the water, etc., as needed
to conform before doing maintenance on the RO system.
Prefilter or RO membrane cartridges
plugged with sediments.
Replace the prefilter cartridge. If rate does not increase, replace
the postfilter cartridge and RO membrane cartridge.
System
makes
lower
amount of product water
than usual
Storage tank air-charge less than 5-7
psi.
Open RO faucet and drain tank until flow slows to a drip. Keep
faucet open and check tank pressure. If low, pressurize to 6 psi.
Close faucet to refill the tank.
High total dissolved sol
ids (TDS) in product wa
ter - flashing red LED
Water supply to the RO system not within
specifications.
Increase water pressure, precondition the water, etc., as needed
to conform before doing maintenance on the RO system.
RO membrane cartridge expended.
Replace the prefilter, postfilter and RO membrane cartridges,
flow control, and screen.
Water leaking from fau
cet airgap hole
Drain side of faucet airgap (3/8” tubing)
plugged, restricted, or incorrectly con
nected to drain point.
Inspect and eliminate restriction or plug. Refer to installation
instructions for proper drain connection.
Continual water flow to
drain
Check valve or automatic shutoff assem
bly plugged, restricted or parts worn
Clean, repair or replace as needed.
Faucet
LED
indicator
light does not function af
ter battery change
Batteries dead.
Replace with new batteries.
Batteries installed incorrectly.
Install batteries correctly.
Static protection of the electronic board
was not discharged.
Remove batteries for one minute and then reinstall.
Paddlewheel jammed.
Repair or replace paddlewheel.
Continual water flow to
drain and no product wa -
ter
Missing flow restrictor in red drain tube or
its corresponding port.
Replace flow restrictor.
Note: Sanitizing is recommended after servicing inner parts of the system(see page 9).