INSTALLATION STEPS (cont.)
C.
THREADED PIPE AND FITTINGS, FIG. 3
MATERIALS AND TOOLS NEEDED: For threaded
pipe installation you will need pipe wrenches, Teflon
tape or pipe joint compound, a union fitting and pipe
nipples. You may also need a pipe threading tool.
Connect the filter housing as typically shown in FIG.
3, page 5. Observe the following:
■ Use Teflon tape or pipe joint compound on all ex
ternal threads.
■
Do not turn pipe or fittings too tightly into the filter
head or you may break it.
■
It is important to have some movement in the sink
cold water pipe. This will allow you to tighten the
union fitting, without damaging the filter head, if
pipe lengths are not exact.
■
Before turning on the water supply remove the
sump from the filter head and install the filter car
tridge {see below).
FILTER CARTRIDGE INSTALLATION
TURN TO PAGE 9 AND FOLLOW ALL STEPS UNDER "FILTER CARTRIDGE REPLACEMENT'