CUSTOMER RESPONSIBILITIES

Thank You for purchasing a Kenmore water heater. Properly

installed and maintained, it should give you years of trouble free

service. If you should decide that you want the new water heater

professionally installed by Sears, call 1-800-4-MY-HOME®. They

will arrange for prompt, quality installation by Sears authorized

contractors.

Abbreviations Found in This instruction Manuai:

CSA- Canadian Standards Association

ANSI - American National Standards Institute

NFPA- National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA - Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA

INTERNATIONAL under American National Standard/CSA

Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1
(current edition).

Read the “Safety Precautions” section, page 3 of this manual

first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It

could cause DEATH, SERIOUS BODILY INJURY AND/OR

PROPERTY DAMAGE.

This manual contains instructions for the installation, operation,

and maintenance of the gas-fired water heater. It also contains

warnings through out the manual that you must read and be

aware of. All warnings and all instructions are essential to the
proper operation of the water heater and your safety. Since

we cannot put everything on the first few pages, READ THE

ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR
OPERATE THE WATER HEATER.

The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence
of local codes, installations shall comply with the current
edition of The National Fuel Gas Code ANSI Z223.1/NFPA

54. This publication is available from the Canadian Standards

Association, 8501 East Pleasant Valley Rd, Cleveland

Ohio 44131, or The National Fire Protection Association, 1
Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do

not understand any portion of the instructions, call the Sears
Service Center.
Carefully plan the place where you are going to put the

water heater. Correct combustion, vent action, and vent

pipe installation are very important in preventing death

from possible carbon monoxide poisoning and fires. See

figure 1.

Examine the location to ensure the water heater complies

with the Facts to Consider About the Location section in this

manual.

For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation procedures.

Instructions may be obtained from the California Office of the

State Architect, 1102 Q Street, Suite 5100, Sacramento, CA
95811. Instructions can also be downloaded to your computer
at WWW.dsa.dgs.ca.gov/Pubs.

Complies with 10 ng/J SCAQMD rule #1121 and districts
having equivalent NOx requirements.

PRODUCT SPECIFICATIONS

MODEL NUMBER

TANK

CAPACITY IN

GALS (LTRS)

TYPE OF

GAS

INPUT

RATE

(Btu/hr)

RECOVERY

RATE GALS.

PER HOUR @

90°F RISE

MINIMUM

VENT PIPE

INCHES

(mm)

DIAMETER

INCHES

(mm)

DIMENSIONS IN

INCHES (mm)

HEIGHT TO

JACKET TOP

153.330632

30(114)

NATURAL

30,000

31.0

3" (76) OR 4" (102)

16-3/8” (415.9)

56 3/8" (1,432)

153.330642

40 (151)

NATURAL

40,000

41.0

3" (76) OR 4" (102)

18” (457)

58 3/8" (1,483)

153.330620

40 (151)

NATURAL

36,000

39.0

3" (76) OR 4" (102)

22” (559)

49" (1,245)

153.330652

50 (189)

NATURAL

40,000

41.0

3" (76) OR 4" (102)

20” (508)

57 3/8" (1,457)