A WARNING

Breathing Hazard - Carbon Monoxide Gas

HigT ettrtude orfioe must be nstalled for
operation above 2,000 feet (610 m).

Contact a qualified rstaki

oi

service

ape-icy

Breathing carbon monoxide can cause b'airr damage or

death Always read and understand instruction nianuai.

Sediment Traps

Water heaters covered in this manual have been tested and

approved for installation at elevations up to 2,000 feet (610

m) above sea level. For installation above 2,000 feet (610 m),

the water heater’s Btu input should be reduced at the rate of
4 percent for each 1,000 feet (305 m) above sea level which

requires replacement of the burner orifice in accordance with the

National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact your

local gas supplier for further information.

Failure to replace the standard orifice with the proper high

altitude orifice when installed at elevations above 2,000 feet
(610 m) could result in improper and inefficient operation of the
appliance, producing carbon monoxide gas in excess of the safe
limits. This could result in serious injury or death. Contact your
local gas supplier for any specific changes that may be required

in your area.

AWARNING

Fire and Explosion Hazard

• Use joint compound or tape

compatiblewith propane.

• Leak test before operating

heater.

• Disconnect gas piping and

shut-off valve before pressure

testing system.

Use pipe joint compound or Teflon tape marked as being resistant

to the action of petroleum (Propane [L.P.]) gases.

The appliance and its gas connection must be leak tested before

placing the appliance in operation.

The appliance and its individual shutoff valve shall be

disconnected from the gas supply piping system during any

pressure testing of that system at test pressures in excess of

1/2 pound per square inch (3.5 kPa). It shall be isolated from

the gas supply piping system by closing its individual manual

shutoff valve during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2 pound per

square inch (3.5 kPa).

Connecting the gas piping to the gas control valve of the water

heater can be accomplished by either of the two methods shown

in Figures 19 and 20.

(R)

TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

AWARNING

Fire and Explosion Hazard

Contaminants in gas lines can
cause fire or explosion.

Clean all gas piping before

installation.

Install drip leg in accordance with
NFPA54.

Contaminants in the gas lines may cause improper operation
of the gas control valve that may result in fire or explosion.

Before attaching the gas line be sure that all gas pipe is clean

on the inside. To trap any dirt or foreign material in the gas
supply line, a drip leg (sometimes called a sediment trap) must
be incorporated in the piping. The drip leg must be readily
accessible. Install in accordance with the Gas Piping section.

Refer to the current edition of the National Fuel Gas Code,

ANSI Z223.1/NFPA54.

A sediment trap shall be installed as close to the inlet of the water

heater as practical at the time of water heater installation. The
sediment trap shall be either a tee fitting with a capped nipple

in the bottom outlet or other device recognized as an effective

sediment trap. If a tee fitting is used, it shall be installed in
conformance with one of the methods of installation, shown in

Figures 19 and 20.

GROUND JOINT

UNION

(OPTIONAL) ,

3” MIN.

(76.2 mm)

GAS CONTROL

VALVE

DRIP LEG

(SEDIMENT TRAP)

FIGURE 19. GAS PIPING WITH FLEXIBLE CONNECTOR.

GROUND JOINT

UNION

(OPTIONAL) ,

BLACK PIPE

GAS CONTROL

/

VALVE

3” MIN.

(76.2 mm)

D

DRIP LEG

(SEDIMENT TRAP)

FIGURE 20. GAS PIPING WITH ALL

BLACK IRON PIPE TO GAS CONTROL.