beautypg.com

Drainage, Installation, How to install – Kenmore 580.72053 User Manual

Page 6

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

INSTALLATION

INSTALLATION

Pick a location which will allow you to blow the cold

air into the area you want. Windows used for

installation must be strong enough to support the

weight of the air conditioner. Good installation with

special attention to the proper position of the unit

will lessen the chance that service will be needed.

HOW TO INSTALL

GUIDE PANELS

Insert the guide panels into the guides of the air
conditioner. Fasten the curtains to the unit with
screws (ITEM A), as shown in FIG. 2.

SEAL STRIP

Cut the adhesive-backed seal strip (ITEM D) to the
window width.

Remove the backing from the seal strip and attach the

seal strip to the underside of the bottom window. (FIG. 3)

SEAL STRIP
(ITEM D)

F1G.3

LOCATING UNIT IN WINDOW

Open the window and mark center line with pencil
on the center of the inner sill, as shown in FIG. 4.

INNER SILL

CENTER LINE

ATTACH L BRACKET

Install the L brackets on the outer sill with the short
side of the bracket against the back of the inner

sill. Install one L bracket 8" to each side of center

line. See FIG. 5.

The bracket helps to hold unit securely in place.

Be sure to place bracket edge flush against back

of inner sill. See FIG. 5.

If air conditioner is blockde by storm window

frame, see step 9.

DRAINAGE

First, be sure to insert the drain pipe into base pan
before installation.

The air conditioner must be installed with a slight tilt

downward for proper water drainage. The air
conditioner will drain the excess condensed water
through the drain pipe.

DRAIN CAP

DRAIN PIPE

DRAIN PIPE

N-

BASE PAN REAR

BASE PAN BOTTOM

FIG. 6