Service and Adjustment (cont’d)

L.P. Gas Conttx>l Valve & Burner

Assembly Replacement

Information

awarning

PROPANE (L.R) GAS CONTROL V>«.VE AND BURNER

ASSEMBLY REPLACEMENT INFORMATION.

For Propane (LR) Gas Modeb Only:

Your vrater heater is equipped with a Propane (LR) gas con-
troi valve and a main burner assembly with left hand thread
for the following fittings and their connections,

* The connection between the manifold and the gas

control valve (A to B) are left hand threads.

• The connection between the main burner orifice

and the manifold (C to D) are left hand threads.

For ordering these replacement parts, please refer to

the "Repair Parts” section of thii manual.

Draining

The ^ter heater should be drained if bcir^ shut down during
freezing temperatures. Also periodic draining and cleaning or
sediment from the tank may he necessary.

Turn the

eas

control knob to the “OFF” position.

CLOSE the cold water inlet valve to the water heater.
OPEN a nearby hot water faucet and leave open to allow for

draining.
Connect a hose to the drain valve and terminate to an adc-
q^te drain.
OPEN the water heater drain valve to allow for tank

draining.

NOTE: If the water heater ts going to be shut down and

drained for an extended period, the drain valve should be

left open with hose connected allowiii^ water to terminate
to an adequate drain.
Close the drain valve.

Follow instructions in the “Filling The Water Heater”

section.
Follow the lighting instructions in the “Lighting” section to
restart the water heater.

Temperature-Pressure

Relief

Valve Operation

The temperature-pressure relief valve must be manually operated

at least once a year.

TEMPERATURE-PRESSURE

REUEF VALVE

DISCHARGE PIPE

Failure to install and maintain a new properly listed tempera­

ture-pressure tdief valve will release the manuhicturer from any
claim which might result from excessive temperature or pressure.

AWARNING

If the temperature-pressure relief valve on the appliance

weeps or discharges periodkaliy, thb msy be due to thermal

expansion. Your water heater may have a check valve
installed In the water line or a water meter with a check

valve. Consult the Sears Service Center for ftirtlier infornia-
tion. Do not plug the temperatur«.pressure relief valve.

AWARNING

When checking the temperature-pressure relief valve opera­
tion, make sure that (I) no one is In Iront of or around the

the temperatwe^Hessure relief valve discharge Ikw,

and (2) that the water manually disdiarged will not cause any
property damage because the water may be extreiTwIy hot

If after manually operating the valve, it foils to completely

reset and continues to release water, immediatdy dose the
cold water inlet to the water heater, follow the draining
insteuctions, and replace the temperature-pressure relief

valve with a new one.