Filter replacement – Coway AP-1008BH User Manual
Page 19
18
Filter
cycles
method
Pre-filter
Every 2~4 weeks
Cleaning
A3
TM
medium filter
Every 4 months
Cleaning
Every 30 months
Replacement
HEPA filter
Every 30 months
Replacement
1. Button indicator is turned on one by one clockwise when the filter
needs to be replaced.
2. Airflow LED indicates a filter that needs to be replaced.
Step 1 LED : HEPA
Step 2 LED : A3
TM
medium
3. When the filter replacement indicator is displayed, the pollution level
indicator is turned off.
4. The filter replacement indicator is displayed for 5 minutes in every half an hour.
5. After replacing filter, push the Reset button one time.
6. When you have replaced a filter before the filter replacement cycle is reached, press and hold the
RESET button for 1 second(forcible reset). The forcible reset initializes all the filter replacement
cycle counters.
CLEANING METHOD
FILTER REPLACEMENT
Maintenance
FILTER REPLACEMENT
■ How to replace filters
∗ Each service life is based on 24-hour use in Speed step 1.
∗ The recommended filter replacement cycles may differ depending on the operating environment.
■ Filter cleaning and replacement cycles
- Check that the ‘front’ sides of filters are in the correct direction.
- To maintain optimal performance of the product, use original coway filters.
- Always unplug the air purifier before replacing filters.
■ Filter replacement indicator
■ Replacing filters
1. When replacing filter, check that the front side is In the correct
direction.
2. With the power is on, press the reset button with a sharp tool.
/