beautypg.com

Whirlpool GLS3064R User Manual

Whmdòor gas built-in cooktop

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

WhMDÒor Gas Built-in Cooktop

/

^»œRPORATlON

PRODUCT MODEL NUMBERS

GLS3064R
GLS3665R

Gas Supply:

This cooktop is factory set for use

with Natural gas. Cooktop can be converted to LP
gas. Provide a gas supply line of

yi'

(1.9 cm) rigid

pipe to the cooktop location. A smaller size pipe on
longer runs may result in insufficient gas supply.
Pipe-joint compounds that resist the action of LP
gas must be used. Do not use TEFLON® tape. With
LP gas, piping or tubing size can be I/

2

" minimum.

Usually,

l

P gas suppliers determine the size and

materials used in the system.

Electrical:

A 120 volt, 60 Hz., AC only, 15-amp

fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is

recommended that a separate circuit serving only

this cooktop be provided.

OVERALL DIMENSIONS

30" (76.2 cm) Model

C

k. 30" {76.2 cm)

B. 20

{51.1 cm)

C. 2 ¡^^/

32

' {7.2 cm)

36" (91.4 cm) Model

C

A. 36" {91.4 cm)

B. 20

{51.1 cm)

C. 2 ¡^^/

32

' {7.2 cm)

Gas and Electric Connection Locations

A

A. 18 "

(45.7 cm) minimum clearance upper cabinet to countertop

B. Cabinet

C. 30" (76.2 cm) on 30" (76.2 cm) models

36" (91.4 cm) on 36" (91.4 cm) models

D. 13"

(33 cm) maximum recommended upper cabinet depth

E. 6 " (15.2 cm) minimum side wall clearance

F. 30 "

(76.2 cm) minimum clearance between top of cooktop

platform and bottom of unprotected wood or metal cabinet
(24" [61 cm] minimum clearance if bottom of wood or metal
cabinet is protected by not less than 1^i" [0.6 cm] flame
retardant millboard covered with not less than No.

28 MSG

sheet steel, 0.015 " [0.04 cm] stainless steel, or

0.024

" [0.06 cm]

aluminum or 0.020 " [0.05 cm] copper)

G.

2 ^/i6 (5.9 cm) minimum distance to rear combustible surface

H.

3 /ie' (8.1 cm) minimum distance to front countertop edge

I. Cutout width -

29 /!' (74.6 cm) on 30" models; 35

{/!' (89.9 cm)

on

36" models

J. Cutout depth -

19 /1' (49.5 cm)

B

A. Gas pressure regulator (supplied) - arrow pointed

toward cooktop

B.

3 prong grounding type outlet with correct polarity

C. 18" (45.7 cm) minimum

D. Gas shutoff valve

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.