Whirlpool GLS3064R User Manual
Whmdòor gas built-in cooktop
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
WhMDÒor Gas Built-in Cooktop
/
^»œRPORATlON
PRODUCT MODEL NUMBERS
GLS3064R
GLS3665R
Gas Supply:
This cooktop is factory set for use
with Natural gas. Cooktop can be converted to LP
gas. Provide a gas supply line of
yi'
(1.9 cm) rigid
pipe to the cooktop location. A smaller size pipe on
longer runs may result in insufficient gas supply.
Pipe-joint compounds that resist the action of LP
gas must be used. Do not use TEFLON® tape. With
LP gas, piping or tubing size can be I/
2
" minimum.
Usually,
l
P gas suppliers determine the size and
materials used in the system.
Electrical:
A 120 volt, 60 Hz., AC only, 15-amp
fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only
this cooktop be provided.
OVERALL DIMENSIONS
30" (76.2 cm) Model
C
k. 30" {76.2 cm)
B. 20
{51.1 cm)
C. 2 ¡^^/
32
' {7.2 cm)
36" (91.4 cm) Model
C
A. 36" {91.4 cm)
B. 20
{51.1 cm)
C. 2 ¡^^/
32
' {7.2 cm)
Gas and Electric Connection Locations
A
A. 18 "
(45.7 cm) minimum clearance upper cabinet to countertop
B. Cabinet
C. 30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
D. 13"
(33 cm) maximum recommended upper cabinet depth
E. 6 " (15.2 cm) minimum side wall clearance
F. 30 "
(76.2 cm) minimum clearance between top of cooktop
platform and bottom of unprotected wood or metal cabinet
(24" [61 cm] minimum clearance if bottom of wood or metal
cabinet is protected by not less than 1^i" [0.6 cm] flame
retardant millboard covered with not less than No.
28 MSG
sheet steel, 0.015 " [0.04 cm] stainless steel, or
0.024
" [0.06 cm]
aluminum or 0.020 " [0.05 cm] copper)
G.
2 ^/i6 (5.9 cm) minimum distance to rear combustible surface
H.
3 /ie' (8.1 cm) minimum distance to front countertop edge
I. Cutout width -
29 /!' (74.6 cm) on 30" models; 35
{/!' (89.9 cm)
on
36" models
J. Cutout depth -
19 /1' (49.5 cm)
B
A. Gas pressure regulator (supplied) - arrow pointed
toward cooktop
B.
3 prong grounding type outlet with correct polarity
C. 18" (45.7 cm) minimum
D. Gas shutoff valve
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 9761893
12-13-05