Floor venting installation

connects to

range exhaust

wall/floor

transition

Left side venting installation

(Requires Kit No. 4315772 availabie

from dealer.)

connects to
range exhaust

Figure 6

Recommended standard fittings

3-1/4"

X

10"

to 6 " = 1 ft.

6"to

3-1/4 "

X

10 " 90“

elbow = 6 ft.

6"to 3-1/4"

X

10 " = 4.5 ft.

3-1/4 "

X

10 " 90“

elbow = = 5 ft.

3-1/4 "

X

10 " wall

cap = 0 ft.

3-1/4 "

X

10 " fiat

eibow = Ï2 ft.

6” duct system

2 —90° elbow

=10ft.

1—wall cap

= Oft.

8 feet straight

= 8 ft.

Length of 6" system = 18 ft.

Recommended standard fittings

3-1/4"X 10"

to 6 " = 4.5 ft.

A

A

elbow

6" to 3-1/4 "

45“eibow

6 " wail

= 5 ft.

xIO" = 1 ft.

= 2.5 ft.

cap = 0 ft.

Note: Never use laundry-type wall caps.

Now start...

With range in kitchen.

1

.

Remove racks and other parts from
Inside oven. Remove venting kit from

storage drawer and remove elbow
taped to cardboard base behind
storage drawer.

2

.

Place one foot on the shipping base.

Tilt range forward slightly to free rear

legs. Gently lower range to floor. Tilt
range backwards until front legs are

free.

Remove shipping materials, tape and
protective film from range. Do Not
remove cardboard shipping base at

this time.

Lower leveling legs approximately

1/4" or to a point where the range

base does not touch the floor.

Defermine which venfing method (left
side, rear wall, or floor) you need to
use. This range is manufactured for
rear wall or through the floor venting.
If through left side venting is desired, a

separate kit (Kit No. 4315772) must be
ordered.

Clearly mark where vent opening will

be made in cabinet opening
according to the venting method
needed. See Venting requirements

tor dimensions.

Recommended duct length

for island or peninsula

installations

Use 6" or 3-1 /4" X 10" duct with a
maximum of 18 feet for duct system.
For best performance, use no more

than three 90° elbows. To calculate
the length of system you need, add
the equivalent feet for each ducf
piece used in the system. See the
following example:

3-1/4 " X 10 " duct system

3-1/4"X 10"
elbow

-6 ft.

T

2-1/2 ft.

i

wall cap

___ 6'"

to 3-1/4""

X

10"

L

___ J transition

Maximum length =18 ft.

90° elbow

1 — wall cap
1 — transition

8-1/2 feet straight

Length of

3-1/4"

X

10" system

= 5 ft.
= 0 ft.
= 4-1/2 ft.

= 8-1/2 ft.

=18 ft.

Using a saber saw, cut a 7-1/2" x
7-1/2" square opening for the vent

duotwork.

8

For rear wall venting: Install wall/floor

fransition fhrough back of cabinef

using 8 wood screws (or anchor bolts
if fastening to drywall or masonry).

Stretch slotted gasket over edge of
wall/floor fransition.

For countertops without a backsplash,

the distance from the rear wall to the
gasket must be at least 3/4";

7/8" maximum.

Panel C