beautypg.com

Front panel removal, Providing electrical power – Whirlpool RCH3660 User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

FRONT PANEL REMOVAL

1.

Remove the three screws that secure the front panel;

lower and remove front panel.

2. This appliance is equipped with copper lead wires. If
connection is made to aluminum house wiring, use only
special connectors which are approved for joining copper

and aluminum wires in accordance with the National
Electrical Code and local codes and ordinances.

Figure 10

PROVIDING ELECTRICAL

POWER

IT IS THE PERSONAL RESPONSIBILITY AND OBLIGA­

TION OF THE CUSTOMER TO CONTACT A QUALIFIED

INSTALLER TO ASSURE THAT THE ELECTRICAL IN­
STALLATION IS ADEQUATE AND IS IN CONFORMANCE

WITH THE NATIONAL ELECTRICAL CODE AND LOCAL
CODES AND ORDINANCES.
1. Connect the wiring to the junction box through flexible

armoured or nonmetallic sheathed copper cable (with

R E M O V E 7 / 8 " D i a K N O C K O U T F O R

ground wire). A suitable strain relief must be provided at
each end of the power supply cable (at appliance and at the

junction box.

Page

Electrical Ground is Required on This Appliance

Recommended Electrical Connection

and Grounding Method

This appliance must be permanently grounded in accor­

dance with the National Electrical Code and local codes and
ordinances.

1. Remove the terminal access cover. (See Figures 11 and
12

) . -

2. Install a strain relief into the opening of the wire junction

box. (Figure 13, pg. 5).

3. Connect the white and black wires of the power supply
cable to the white and black wire leads inside the terminal
access box.

4. Connect the green ground wire from the power supply

cable to the end of the green ground wire provided in termi­
nal access box.

5. Replace the terminal access cover.

6. Replace front panel after microwave is installed and

leveled using leveling bolts as shown in Figure 14.

—ALTERNATE GROUNDING —

If the recommended grounding method is impossible,
permanently ground the appliance from the green ground

wire (located in the terminal access box) to a grounded cold
water pipe* using a separate, green colored, insulated
copper conductor of appropriate size (no.16 minimum).

'Cold water pipe must have metal continuity to electrical
ground and not be interrupted by plastic, rubber or other

electrically insulating connectors (including water meter or
pump) without adding a jumper wire to these connections.

CAUTION:
(a) DO NOT GROUND TO GAS SUPPLY PIPE.
(b) DO NOT CONNECT TO ELECTRICAL SUPPLY UNTIL

APPLIANCE IS PERMANENTLY GROUNDED.

4