Before you start...

^WARNING

File Hazard

• Never install dryer up

against draperies or curtains
or on carpet.

• Keep any and all items (rom

falling or collecting behind
the dryer.

• Replace all access panels

before operating dryer.

Failure to follow Ihese

instructions could result in a

lire or explosion.

. If you smell gas:

1. Open windows.

2. Don't touch electrical switches.

3. Extinguish any open flame.

4. Immediately call your gas
supplier.

. Do Not store or use gasoline or

other flammable vapors and
liquids in the vicinity of this or
any other appliance. The

fumes can create a lire hazard
or explosion.

Mark an X across the letter or
number as you complete each step.

A

You need these tools to install

• your Whirlpool gas dryer. Get

them together In one place to keep

B

Check the spot where

■ you're going to install the

dryer...proper installation is

your responsibility.

C

Make sure you have

■ everything necessary for

proper installation. You'll need:

. To meet code requirements: some

codes keep from or limit installation
of clothes dryers in garages,

closets, mobile homes and
sleeping quarters, (Check with your

local building inspector.)

Important: Observe all governing

codes and ordinances.

. To check utilities: proper gas and

electric supply connections

should be available.

. To check exhaust requirements:

a four inch metal exhaust duct

is required.

Size: Must be large enough to fully
open dryer door. For recessed or
closet installation spocing, see back
cover.

Support: The floor must be oble to
support the appliance weight of

175 pounds.

Level floor: Maximum floor slope
under dryer - 1 inch.

Protection (rom the weather: Proper

operation of dryer cycles requires

temperatures above 45o F,, or the

dryer may not shut off when
automatic cycles are used.

Panel A

This appliance is suitable tor mobile

home Installations. The installation

ot the dryer must contorm to the
Manutactured Home Constnjctlon and
Sotety Standard, Title 24 CFR, Part 3280
(lormerly the Federal Standard tor
Mobile Home Construction and Sotety,

Title 24, HUD, Part 280).

For mobile home use. this appliance
MUST be fastened to the floor and

MUST be exhausted to the outside.

Order Mobile Flome Installation Kit

No. 346765 from your Whirlpool dealer.
Kit includes the necessary fastening

hardware and detailed installation
instructions. Exhaust system hardware
is also available through your
Whirlpool dealer.This installation must
conform with American National
Standard, National Fuel Gas Code

ANSI Z223.1 - latest edition, and all

local codes and ordinances. Input

ratings shown on the rating plate
(serial tag) are for elevations up to

2,000 feet. For elevations above 2.000

feet, ratings should be reduced at a

rate of 4% for each 1,000 feet above

sea level.

Gas supply

requirements

^WARNING

Fire Hazard

• This dryer must be connected to

a regulated gas supply. Failure

to do so could cause high-

pressure gas release, resulting in
a fire or explosion.

• Have the LP. gas checked by a

qualified person before installing
the dryer. The LP. gas supply
must not exceed a pressure of

13" water column.

• New flexible tubing should be

used. Reusing old tlexible
tubing might result in possible

leaks or fire hazard.

Failure to follow these instructions

may result in fire or explosion.

OBSERVE ALL GOVERNING

CODES AND ORDINANCES

A

First make certain that this dryer

a is equipped with the correct

burner for the particular type of gas in

the home. Burner informotion will be
found on the rating plate in door well

of the oppliance. If this information
does not agree wit the type of gas
available, see your dealer,

B.;

This dryer Is

■ equipped for

use with NATURAL GAS.
It is certified by A.G.A.

for manufactured, mixed and L.P.
gases with appropriate conversion.
No attempt shall be made to convert

the appliance from the gas specified

on the rating plate for use with a
different gas without consulting the

serving gas supplier. Conversion

must be done by a qualified service

technician. Gas conversion kit part

numbers ore iisted on the gas valve
burner base.

C

Provide a gas supply line to the

■ dryer location. When rigid pipe

is used it should be 1/2 inch IPS. When

acceptable to the gas supplier, 3/8
inch approved tubing may be used

for lengths under 20 feet. For lengths

over 20 feet, larger tubing should be
used. Pipe joint compounds resistant

to the action of LP gas must be used.

D

The supply line should be
a equipped with a shutoff valve.
This valve should be located in the

some room as the dryer and should

be in a location that allows ease of

opening and closing. Do not block
access to shutoff valve.

E

lf the dryer is installed in a

a

confined area such os a bed­

room, bathroom or closet, it must be

exhausted to the outside and
provision made for enough air for
combustion and ventilation. (Check
governing codes and ordinances.)
Also refer to the section of this
instruction covering Recessed or
Closet Installations.

F.

If local codes
permit, it is
recommended
that flexible metal
tubing,design

certified by the
American Gas
Association, be used for connecting
the appliance to the gas supply line.

(The gas pipe which extends through

the lower rear of the appliance has

3/8 inch male pipe thread.)

G

if rigid pipe Is used as a gas

■ supply line, a combination of [,

pipe fittings must be used to obtain oh

in-line connection to the dryer.

H

Make sure that lower edges of

a

the cabinet, plus the back and

bottom sides of the dryer are free of

obstructions to permit adequate

clearance of air openings for
combustion air. See Recessed Area
Instructions, back page, for minimum
spacing requirements.

I

For ease of installation, operation

a and servicing (if ever needed)

adequate space should be provided

around the dryer.

J

A 1/0 Inch NPT plugged tapping,

, accessible for test gauge

connection, must be installed
immediately upstream of the gas

supply connection to the dryer.

The dryer and its individual shutoff

valve must be disconnected from the

gas supply piping system during any

pressure testing of that system of

test pressures in excess of 1/2 psig
(3.45 kPa).

The dryer must be Isolated from the

gas supply piping system by
closing its individual manual shutoff

valve during any pressure
testing of the gas supply piping system

at test pressures equal to or
less that 1/2 psig (3.45 kPa).
Important: Observe all governing

codes and ordinances.

K

The dryer shutoff valve and the

a

wiring diagram are located

behind the lower front access panel.

Open the access panel by pushing
down on the locking clips with a small,

flat-blade screwdriver, and pulling

panel forward. The clips are located
on top of the panel 3 inches In from
each side. The panel is hinged at the
bottom. Close the access panel after
sen/icing. Do Not operate the dryer

with the access panel open,

L

If dryer will not operate, check

a

the followihg to be sure that:

1. Electric supply is connected.

2. Fuse is intact and tight.
3. Door Is closed.

4, Controls are set in a running or

"On' position.

5. Start button has been pushed

firmly or the power control lever
moved upward to start.

6. Gas shutoff valves are open both

on dryer and on supply lines.