RANGE HOOD BLOWER ORIENTATION
NOTE; Before reinstalling the Blower Assembly, check the
damper for free operation. Open the damper blade and check for
any restrictions in the duct system. Check installation instructions
for proper duct sizing.
Correct Blower orientation is imperative. Incorrect installation
will drastically cut air flow and cause Blov^er to run at maximum
RPM regardless of motor speed control setting.
VERTICAL DISCHARGE:
1. Figure 1 shows the proper Blower Assembly orientation for
vertical discharge.
2. From the Blower position shown in Figure 1,
Assembly vertically into mounting position.
lift the Blower
3. The 3" Blower discharge surface should now be flush against
top
o! hood. This will allow proper air flov/ from the Blower through
the top vent. (The wider 5" surface will be to the rear).
HORIZONTAL DISCHARGE:
1. Figure 2 shows the proper Blower Assembly orientation for
horizontal discharge.
F I G U R E I
V E R T I C A L D I S C H A R G E
2. From the Blower position shown in Figure 2, lift the Blower
Assembly vertically into position.
3. The 3" Blower discharge surface should now be flush against
rear
of hood. This will allow proper air flow from the Blower
through the rear vent. (The wider 5" surface w'lll be to the top).
F I G U R E 2
H O R I Z O N T A L D I S C H A R G E