beautypg.com

Wall mounted low-cabinet type, Water quality requirement – Cleveland Range Enodis PDW-4 User Manual

Page 2

background image

WALL MOUNTED

LOW-CABINET TYPE

1” IPS common drain.

Do not connect other units
to this drain.

Do not use PVC pipe for
drain.

(NOT TO SCALE)

SECT.

VI

PAGE

10

0707

Litho in U.S.A.

Each compartment has capacity for:
Eight,

12˝ x 20˝ x 2

1

2

˝

Cafeteria Pans or

Six,

12˝ x 20˝ x 4˝

Cafeteria Pans or

Four,

12˝ x 20˝ x 6˝

Cafeteria Pans or

Four,

18˝ x 26˝

Bun Pans

Many regional, state and local codes exist and it is
the responsibility of the owner and installer to com-
ply with those codes.

Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included
among those approval agencies are: UL, ULC, NSF,
and CSA.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be
necessary. The fact that a water supply is potable is not
proof that it will be suitable for the generator.

Cleveland Range reserves right of design improvement or modification, as warranted.

Right - 3”, Left - 3”, Rear - 3”

(12” on control side if
adjoining wall or equipment
is over 30” high for service
access)

Contact factory for
variances to clearances.

This manual is related to the following products: