beautypg.com

Troubleshooting, For further technical support – Champion Power Equipment 66520 User Manual

Page 22

background image

19

REV 66520-20140303

ENGLISH

66520

TROUBLESHOOTING

For further technical support:

Technical Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
[email protected]

Problem

Cause

Solution

Semi-trash pump will not start

No fuel

Add fuel

Faulty spark plug

Replace spark plug

Semi-trash pump will not start; Semi-trash
pump starts but runs roughly

Low oil level

Fill crankcase to the proper level; place
semi-trash pump on a flat, level surface

Choke in the wrong position

Adjust choke

Spark plug wire loose

Attach wire to spark plug

Semi-trash pump shuts down during
operation

Out of fuel

Fill fuel tank

Low oil level

Fill crankcase to the proper level; place
semi-trash pump on a flat, level surface

Semi-trash pump overheating or
performing poorly

Strainer or hose clogged

Remove debris from strainer or hose

Pump not primed

Re-prime pump

Suction hose out of water

Place suction hose under the surface of
the water

Head limit exceeded

Relocate pump so suction head is less
than discharge head (maximum 98 feet)

Air leak

Tighten connectors and clamps or replace
seal packing