MAINTENANCE AND STORAGE

Air Filter

1. Remove the maintenance cover.
2. Locate the air filter plastic cover.
3. Unsnap the locking hinge on the cover.
4. Remove the old filter.
5. Place the new filter in the assembly.
6. Re-snap the hinge on the air filter cover.
7. Reinstall the maintenance cover and tighten the

cover screw securely.

Use a damp cloth to clean exterior surfaces of the
generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the generator.

Cleaning

DO NOT spray generator with water.

CAUTION

Water can contaminate the fuel system.

Adjustments

The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. CPE
recommends that you contact our service line at
1-877-338-0999 for all other service and/or adjustment
needs.

Maintenance Schedule

Follow the service intervals indicated in the following
maintenance schedule.
Service your generator more frequently when operating
in adverse conditions.
Contact our help line at

1-877-338-0999 to locate the

nearest Champion Power Equipment certified service
dealer for your generator or engine maintenance needs.

Spark Arrester

1. Allow the engine to cool completely before servicing

the spark arrester.

2. Remove the two screws holding the cover plate

which retains the end of the spark arrester to the
muffler.

3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the spark

arrester screen with a wire brush.

5. Replace the spark arrester if it is damaged.
6. Position the spark arrester in the muffler and attach

with the two screws.

Failure to clean the spark arrester will result in

degraded engine performance.

CAUTION

*To be performed by knowledgeable, experienced owners or
Champion Power Equipment certified dealers.

Every 8 hours or daily

Check oil level

Clean around air intake and muffler

First 5 hours

Change oil

Every 50 hours or every season

Clean air filter

Change oil if operating under heavy load or in hot environments

Every 100 hours or every season

Change oil

Clean/Adjust spark plug

Check/Adjust valve clearance*

Clean spark arrester

Clean fuel tank and filter*

Every 250 hours

Clean combustion chamber*

Every 3 years

Replace fuel line

Generator Battery

This product is equipped with an automatic battery
charging circuit. The battery will receive charging
voltage when the engine is running. The battery will
maintain a proper charge if the unit is used on a regular
basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle
charger (included) or battery maintainer to keep the
battery properly charged. If the battery is not able to
start the engine, it can be started by manually pulling
the engine recoil cord. If the battery voltage is extremely
low, the charging circuit may not be able to re-charge
the battery. In this case, the battery must be connected
to a standard automotive style battery charger for re-
charging before it can be used.