Controls and features, Power panel – Champion Power Equipment 41570 User Manual
Page 9
REV 41570-20140522
6
41570
ENGLISH
Power Panel
CONTROLS AND fEATURES
4
1
2
3
5
7
6
9
8
(1) Ignition Switch – Used to start or stop the
generator.
(2) Battery Switch – Enables/disables starting
electrically – via remotely or by ignition switch.
(3) 120/240 Volt AC, 30 Amp Twist-Lock Receptacle
(NEMA L14-30R) –
May be used to supply
electrical power for the operation of 120
and/or 240 Volt AC, 30 Amp, single phase 60 Hz
electrical loads.
(4) Circuit Breakers – Protects the generator against
electrical overloads. Push to reset breaker.
(5) Intelligauge – Three mode digital meter for
displaying running hours, voltage and hertz.
(6) 120/240 Volt AC, 50 Amp Receptacle
(NEMA 14-50R) – May be used to supply
electrical power for the opertaion of 120
and/or 240 Volt AC, 50 Amp, single phase 60 Hz
electrical loads.
(7) 120 Volt AC, 30 Amp Receptacle (NEMA TT-30R)
–
May be used to supply electrical power for the
operation of 120 Volt AC, 30 Amp, single phase
60 Hz electrical loads.
(8) 120 Volt AC, 20 Amp Duplex (2)
(NEMA 5-20R) –
May be used to supply electrical
power for the operation of 120 Volt AC, 20 Amp,
single phase 60 Hz electrical loads.
(9) Ground Terminal – Consult an electrician for local
grounding regulations.