D--9--610 Page 13
Blower
Ambient Temperature
Discharge
Temperature
Less than10_ F *
10_ F to 32_ F **
32_ F to 90_ F
Greater than 90_ F
Less than 32_ F
ISO 100 }
ISO 100 }
(0_ C)
32_ F to 100_ F
ISO 100 }
ISO 100 }
ISO 150 }
(0_ C to 38_ C)
100_ F to 225_ F
ISO 100 }
ISO 100 }
ISO 150 }
ISO 220 }
(38_ C to 105_ C)
225_ F to 300_ F
ISO 150 }
ISO 150 }
ISO 220 }
ISO 220 }
(105_ C to 149_ C)
Greater than 300_ F
*** }
*** }
(149_ C)
*
For ambient temperatures less than 10_ F, but not less than --20_ F, the use of oil sump heaters,
heated enclosures or synthetic lubricant is required.
**
For ambient temperatures 10_ F to 32_ F, the use of oil sump heaters, heated enclosures or
synthetic lubricant is recommended.
***
The lubricant viscosity must be 70 SUS minimum at the lubricant operating temperature.
The pour point of the lubricant should be at least 5_ to 10_ F below the minimum expected ambient
temperature.
For continuous operation, where the lubricant temperature exceeds 200_ F, synthetic lubricant
is recommended.
}
The recommended operating range for AEON PD Synthetic Lubricant.