Instructions for casters – Cleveland Range Convotherm Combination Oven-Steamer Gas 20.20 User Manual
Page 8
C. SPECIAL INSTRUCTIONS FOR CASTER EQUIPPED COMBI STANDS AND COMBIS
1. Read all instructions before beginning installation.
2. Level the floor if needed.
3. NOTE: Combis on caster-equipped stands have less adjustment for level than adjustable
foot equipped stands.
4. The front wheels of caster-equipped stands and Combis have locks. Check the caster
locks for function and position before installation.
5. Follow the separate instructions included with the Stand, Stacking Kit, or Caster Kit.
6. Make sure the Stand, Stacking Kit, or Caster Kit matches the Combi(s).
7. Use only genuine Cleveland Range Stands, Stacking Kits, Caster Kits, and replacement
parts.
8. Use of Stands, Stacking Kits, Caster Kits, and replacement parts other than genuine
Cleveland Range Stands, Stacking Kits, and Caster Kits and replacement parts can
result in injury and / or catastrophic equipment failure, and voids the Warranty.
9. The appliance must be secured to building structure, to prevent any strain on the utility
connections, and to help reduce the risk of electric shock.
10. The strain relief (restraining device) must be installed to limit the movement of the
appliance without depending on the connector and the quick-disconnect device or its
associated piping (gas, water, or electric). See separate instructions for attachment
location and other details.
11. Connect the strain relief (restraining device) BEFORE starting the Combi
12. If the strain relief (restraining device) must be disconnected, it must be reconnected
after the Combi has been returned to its originally installed position BEFORE restarting
the Combi.
13. Prepare the installation location as described in the Combi Installation Manual.
14. For GAS (OGB, OGS) Combis: The installation of the gas supply shall be made with a
connector that complies with the Standard for Connectors for Movable Gas Appliances,
ANSI Z21.69 / CSA 6.16, and a quick disconnect device that complies with the Standard
for Quick Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 / CSA 6.9.
15. The appliance shall be installed using flexible conduit.
16. Mechanically secure the flexible conduit to the Combi’s electrical access hole.
6