beautypg.com

Cleveland Range Convotherm Combination Oven-Steamer Gas 20.20 User Manual

Page 54

background image

Every 120 seconds the rotation of the motor reverses.

NOTE: If the temperature is less than 212 degrees F than fan will be

pulsed on for 2 seconds every 60 seconds after the cabinet set temp (B6)
and the bypass probe (B5) are satisfied.

c

Hot air heat circuit is energized

• A signal is sent from terminal 2 of connector X24 on the Gas Board (A20) to

terminal 4 of connector X2 on the Upper Hot Air Power Burner and Fan
Control (U20) selecting the set speed of the combustion blower.

When this speed is attained the signal is sent from terminal 2 of connector

X2 on the Upper Hot Air Power Burner and Fan Control (U20) to terminal
3 of connector X24 on the Gas Board (A20)

• A request for heat is sent from terminal 3 of connector X20 on the Gas Board

(A20) to terminal 10 on connector X1 on the Upper Hot Air Control Module
(N20)

24 VAC is sent from terminal 2 of connector X2 on the Upper Hot Air

Control Module (N20) to the hot surface igniter (R20).

The gas valve is energized allowing gas and air into the burner chamber to

be ignited by the hot surface igniter.

The Upper Hot Air Burner Control Module (N20) senses at least 1.5 micro

amps DC from the Flame sensor (P1) at terminal 3 of connector X2 and
sends a signal from terminal 2 of connector X1 to terminal 10 of connector
X25 on the Gas Board (A20)

d

When the Upper Burner Assembly has proven flame, the Lower

Hot Air heat

circuit is energized
• A signal is sent from terminal 8 of connector X24 on the Gas Board (A20) to

terminal 4 of connector X2 on the Lower Hot Air Power Burner and Fan
Control (U21) selecting the set speed of the combustion blower.

When this speed is attained the signal is sent from terminal 2 of connector

X2 on the Hot Air Power Burner and Fan Control (U21) to terminal 8 of
connector X24 on the Gas Board (A20)

• A request for heat is sent from terminal 3 of connector X22 on the Gas Board

(A20) to terminal 10 on connector X1 on the Hot Air Control Module (N22)

24 VAC is sent from terminal 2 of connector X2 on the Hot Air Control

Module (N20) to the hot surface igniter (R20).

The gas valve is energized allowing gas and air into the burner chamber to

be ignited by the hot surface igniter.

The Hot Air Burner Control Module (N20) senses at least 1.5 micro amps

DC from the Flame sensor (P1) at terminal 3 of connector X2 and sends a
signal from terminal 2 of connector X1 to terminal 10 of connector X25
on the Gas Board (A20)

e

The heat circuit will remain energized until the cabinet set temperature is reached

f

When the condensate box is heated to 140 degrees F at the B3 probe, 120 VAC is

sent from terminal 5 of connector X12 to the condenser valve (Y1) until the
temperature drops.

g

If the “Crisp and Tasty” mode is selected