Temperature correction factors for membrane – AXEON BT-Series User Manual
Page 33

33
BT – Series User’s Manual
MKTF - 206
06/12
TEMPERATURE CORRECTION FACTORS FOR MEMBRANE
Find the temperature correction factor (TCF) from the table below. Divide the rated
permeate flow at 77°F by the temperature correction factor. The result is the permeate
flow at the desired temperature. (See example on the next page)